ArticleNan fang yi ke da xue xue bao = Journal of Southern Medical University2024
[Low-dose CT reconstruction based on high-dimensional partial differential equation projection recovery].
Article in Nan fang yi ke da xue xue bao = Journal of Southern Medical University, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed.
- A low-dose CT reconstruction method using sub-pixel anisotropic diffusion.Nan fang yi ke da xue xue bao = Journal of Southern Medical University · 2025Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
objectiveWe propose a low-dose CT reconstruction method using partial differential equation (PDE) denoising under high-dimensional constraints.
methodsThe projection data were mapped into a high-dimensional space to construct a high-dimensional representation of the data, which were updated by moving the points in the high-dimensional space. The data were denoised using partial differential equations and the CT image was reconstructed using the FBP algorithm.
resultsCompared with those by FBP, PWLS-QM and TGV-WLS methods, the relative root mean square error of the Shepp-Logan image reconstructed by the proposed method were reduced by 68.87%, 50.15% and 27.36%, the structural similarity values were increased by 23.50%, 8.83% and 1.62%, and the feature similarity values were increased by 17.30%, 2.71% and 2.82%, respectively. For clinical image reconstruction, the proposed method, as compared with FBP, PWLS-QM and TGV-WLS methods, resulted in reduction of the relative root mean square error by 42.09%, 31.04% and 21.93%, increased the structural similarity values by 18.33%, 13.45% and 4.63%, and increased the feature similarity values by 3.13%, 1.46% and 1.10%, respectively.
conclusionThe new method can effectively reduce the streak artifacts and noises while maintaining the spatial resolution in reconstructed low-dose CT images.