ArticleACS omega2024
Research on the Law of Coal Pillar Spontaneous Combustion and Fire Prevention and Control Technology.
Article in ACS omega, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
3 citing papers in PubMed.
- Classification analysis of coal wall failure modes and grey system theory-based evaluation methodology for influencing factors.Scientific reports · 2026Article
- Article
- Fire Prevention and Extinguishing Characteristics of AlGels (Basel, Switzerland) · 2025Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
In coal pillar fires, the fire source is hard to be detected and the adjacent goaf is extremely likely to be affected. Such fires would give rise to thermal and dynamic disasters in mines, further causing casualties and environmental disruption. In this study, with the coal pillar spontaneous combustion (CPSC) accident in Chahasu Coal Mine taken as the research object, the oxygen uptake and limit of oxygen concentration of CPSC were explored. Based on the research results, a similar model was constructed, where a control group was used to simulate the hazardous area of CPSC in a bid to investigate the law of CPSC. Moreover, the polymer colloid perfusion system was constructed and the drilling parameters and perfusion process parameters were determined, and practices concerning spontaneous fire control were carried out. Here are the conclusions: First, air leakage in the coal pillar may lead to coal spontaneous combustion due to the impact of rib spalling, threatening 2-6 m above the middle of the coal pillar at a shallow position. Second, coal pillar grouting, injecting polymer colloids for cooling, and coal pillar cement reinforcement prove to be effective ways to prevent CPSC fires and combat recombustion.
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.