ArticleCJC open2024
Leadless Pacemaker Implantation in Patients With a Prior Conventional Pacing System.
Article in CJC open, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
6 citing papers in PubMed.
- Case Report: Sequential leadless pacing after battery depletion in a patient with recurrent device-related infection.Frontiers in cardiovascular medicine · 2026Article
- Leadless pacemaker in atrioventricular block patients with specific indications: a systematic review.Frontiers in cardiovascular medicine · 2026Review
- Safety and efficacy of completely transthoracic echocardiography guided leadless pacemaker implantation assisted by Panna guide wire: initial clinical experience.Frontiers in cardiovascular medicine · 2026Article
- [Leadless pacing: DDD-all goals achieved?]Herzschrittmachertherapie & Elektrophysiologie · 2025Review
- Retrospective evaluation of the predictive value of acute pacing capture threshold for long-term outcomes in Chinese patients with leadless pacemakers.Scientific reports · 2025Article
- Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
11 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Background: Leadless pacing has been established as an alternative approach to transvenous devices for selected patients. Often, leadless pacemaker (LP) implantation is a de novo procedure, but in an increasing number of patients, an LP is used after previous implantation of a conventional pacing system (CPS). Methods: A retrospective analysis was conducted of the efficacy and safety of LP implantation in the context of a previously implanted CPS, from 2 large Swiss centres. Results: A total of 257 consecutive patients undergoing LP implantation were included. They were divided into 2 groups: group 1 consisted of 233 patients who did not have a previous CPS, and group 2 consisted of 24 patients with an in situ CPS. In group 2, a total of 20 patients (83%) required transvenous lead extraction due to infection, malfunction, or other reasons. In 3 patients with device-related infection, lead extraction and LP implantation was performed as a single procedure, whereas in the remaining 11 cases, a time window occurred between the 2 procedures (median: 11.5 days; range: 2-186 days). Electrical device parameters at implantation and during follow-up did not differ between the 2 groups (mean: 12.5 ± 9.3 months). Eight major periprocedural complications (3.1%) were encountered (4 pericardial effusions, 3 instances of femoral bleeding, and 1 instance of intra-abdominal bleeding) in the entire cohort within a 30-day period. No complications occurred in the group with a previous device. No infections were registered, even when complete extraction of an infected CPS was performed prior to LP implantation. Conclusions: Implantation of an LP in patients with a prior CPS (with or without extraction of the previous system) was effective and safe in our population of patients.
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.