Evidence map›Paper›PMID 38708054›Full record

ArticleCJC open2024

Leadless Pacemaker Implantation in Patients With a Prior Conventional Pacing System.

Julius Jelisejevas, François Regoli, Daniel Hofer, Giulio Conte, Tardu Oezkartal, Ardan M Saguner, Maria Luce Caputo, Lorenzo Grazioli, Jan Steffel, Angelo Auricchio and 1 more

Abstract read
In one paragraph

Article in CJC open, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

6 citing papers in PubMed.

  1. Article
  2. Review
  3. Article
  4. [Leadless pacing: DDD-all goals achieved?]Herzschrittmachertherapie & Elektrophysiologie · 2025
    Review
  5. Article
  6. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

11 authors.

Julius JelisejevasDepartment of Cardiology, University Hospital Zurich, Zurich, Switzerland.
François RegoliFondazione Cardiocentro Ticino, Lugano, Switzerland.
Daniel HoferDepartment of Cardiology, University Hospital Zurich, Zurich, Switzerland.
Giulio ConteFondazione Cardiocentro Ticino, Lugano, Switzerland.
Tardu OezkartalFondazione Cardiocentro Ticino, Lugano, Switzerland.
Ardan M SagunerDepartment of Cardiology, University Hospital Zurich, Zurich, Switzerland.
Maria Luce CaputoFondazione Cardiocentro Ticino, Lugano, Switzerland.
Lorenzo GrazioliFondazione Cardiocentro Ticino, Lugano, Switzerland.
Jan SteffelDepartment of Cardiology, University Hospital Zurich, Zurich, Switzerland.
Angelo AuricchioFondazione Cardiocentro Ticino, Lugano, Switzerland.
Alexander BreitensteinDepartment of Cardiology, University Hospital Zurich, Zurich, Switzerland.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: Leadless pacing has been established as an alternative approach to transvenous devices for selected patients. Often, leadless pacemaker (LP) implantation is a de novo procedure, but in an increasing number of patients, an LP is used after previous implantation of a conventional pacing system (CPS). Methods: A retrospective analysis was conducted of the efficacy and safety of LP implantation in the context of a previously implanted CPS, from 2 large Swiss centres. Results: A total of 257 consecutive patients undergoing LP implantation were included. They were divided into 2 groups: group 1 consisted of 233 patients who did not have a previous CPS, and group 2 consisted of 24 patients with an in situ CPS. In group 2, a total of 20 patients (83%) required transvenous lead extraction due to infection, malfunction, or other reasons. In 3 patients with device-related infection, lead extraction and LP implantation was performed as a single procedure, whereas in the remaining 11 cases, a time window occurred between the 2 procedures (median: 11.5 days; range: 2-186 days). Electrical device parameters at implantation and during follow-up did not differ between the 2 groups (mean: 12.5 ± 9.3 months). Eight major periprocedural complications (3.1%) were encountered (4 pericardial effusions, 3 instances of femoral bleeding, and 1 instance of intra-abdominal bleeding) in the entire cohort within a 30-day period. No complications occurred in the group with a previous device. No infections were registered, even when complete extraction of an infected CPS was performed prior to LP implantation. Conclusions: Implantation of an LP in patients with a prior CPS (with or without extraction of the previous system) was effective and safe in our population of patients.

Identifiers

PMID38708054
PMCPMC11065736

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.