Evidence map›Paper›PMID 38707769›Full record

ArticleClinical ophthalmology (Auckland, N.Z.)2024

Surgical Efficiency Comparison Between Two Phacoemulsification Systems.

Marta Ibarz-Barberá, Paz Orts-Vila, Fátima Martínez-Galdón, Noemí Martín-García, Pedro Tañá-Rivero

Abstract read
In one paragraph

Article in Clinical ophthalmology (Auckland, N.Z.), 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Review
  2. Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Marta Ibarz-BarberáCataract and Refractive Surgery Department, Madrid, Spain.
Paz Orts-VilaCataract and Refractive Surgery Department, Alicante, Spain.
Fátima Martínez-GaldónCataract and Refractive Surgery Department, Madrid, Spain.
Noemí Martín-GarcíaCataract and Refractive Surgery Department, Alicante, Spain.ORCID 0000-0002-1683-6318
Pedro Tañá-RiveroCataract and Refractive Surgery Department, Alicante, Spain.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Purpose: To assess the surgical efficiency in cataract surgery comparing two phacoemulsification systems. Methods: Prospective, consecutive-comparative study in a two-site private practice. Three hundred and one eyes undergoing standard or femtosecond laser-assisted (FLACS) cataract surgery with either the R-Evo Smart (BVI, Waltham, USA) and/or the Centurion Vision System (Alcon, Fort Worth, USA). Preoperative eye characteristics (degree of cataract using the lens opacities classification system LOCS III grading) and intraoperative outcomes (total ultrasound time and total estimated fluid aspirated/drainage bag weighting) were registered in all cases. Results: One hundred and fifty-five eyes undergone cataract surgery with the R-Evo Smart and 146 eyes with the Centurion Vision System phacoemulsification systems. Mean cataract grade was 3.07 ± 0.78 and 2.96 ± 0.85 for the R-Evo Smart and Centurion Vision System groups, respectively (p = 0.12). Mean total ultrasound time was 18.99 ± 12.85 and 40.24 ± 21.91 seconds for the R-Evo Smart and Centurion Vision System groups, respectively (p < 0.01). Mean total estimated fluid aspirated/drainage bag weighting was 53.00 ± 14.56 g and 54.33 ± 14.88 cc for the R-Evo Smart and Centurion Vision System groups, respectively (p = 0.21). Considering non-FLACS surgery (98 eyes with the R-Evo Smart and 63 eyes with the Centurion Vision System), mean cataract grade was 2.95 ± 0.74 and 2.97 ± 0.91 for the R-Evo Smart and Centurion Vision System groups, respectively (p = 0.44). Mean total ultrasound time was 19.96 ± 11.20 and 42.84 ± 28.35 seconds for the R-Evo Smart and Centurion Vision System groups, respectively (p < 0.01). Mean total estimated fluid aspirated/drainage bag weighting was 55.95 ± 14.76 g and 55.97 ± 13.62 cc for the R-Evo Smart and Centurion Vision System groups, respectively (p = 0.49). No adverse events were found in the two groups of eyes. Conclusion: The objective measurement of surgical efficiency through total ultrasound time during lens removal and fluid consumption during both lens removal and irrigation/aspiration proved R-Evo Smart to be an efficient phacoemulsification platform, in comparison with the current standard of care Centurion Vision System.

Indexed as

cataractestimated fluid aspiratedphacoemulsificationsurgical efficiencyultrasound time

Identifiers

PMID38707769
PMCPMC11066661

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.