Evidence map›Paper›PMID 38707765›Full record

ArticleApplied magnetic resonance2023

EPR Viscometric Measurements Using a

Murugesan Velayutham, Martin Poncelet, Jessica A Perini, Justin T Kupec, Matthew J Dietz, Benoit Driesschaert, Valery V Khramtsov

Abstract read
In one paragraph

Article in Applied magnetic resonance, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Murugesan VelayuthamIn Vivo Multifunctional Magnetic Resonance center, Robert C. Byrd Health Sciences Center.
Martin PonceletIn Vivo Multifunctional Magnetic Resonance center, Robert C. Byrd Health Sciences Center.
Jessica A PeriniDepartment of Medicine.
Justin T KupecDepartment of Medicine.
Matthew J DietzDepartment of Orthopedics.
Benoit DriesschaertIn Vivo Multifunctional Magnetic Resonance center, Robert C. Byrd Health Sciences Center.
Valery V KhramtsovIn Vivo Multifunctional Magnetic Resonance center, Robert C. Byrd Health Sciences Center.

Funding

In vivo monitoring of tumor microenvironment regulation for macrophagesR01CA194013 · NCI · WEST VIRGINIA UNIVERSITY · PI Timothy D Eubank, Valery V Khramtsov · 2015 to 2026
$3.5M
Profiling chemical tumor microenvironment: Application for diagnostics & therapyR01CA192064 · NCI · WEST VIRGINIA UNIVERSITY · PI EUBANK, TIMOTHY D, KHRAMTSOV, VALERY V · 2015 to 2024
$3.4M
Biocompatible triarylmethyl radical-based dendrimers as nonmetallic contrast agents for MRIR01EB032321 · NIBIB · WEST VIRGINIA UNIVERSITY · PI DRIESSCHAERT, BENOIT · 2022 to 2025
$1.5M
Biocompatible Magnetic Resonance Probes for in vivo Concurrent Profiling R00EB023990 · NIBIB · WEST VIRGINIA UNIVERSITY · PI DRIESSCHAERT, BENOIT · 2019 to 2021
$730k
Imaging enzyme activity by Overhauser-enhanced MRIR21EB028553 · NIBIB · WEST VIRGINIA UNIVERSITY · PI DRIESSCHAERT, BENOIT · 2020 to 2022
$599k
Electron Spin Resonance Microfluidics as a new tool in chemical single cell population analysisR21GM143595 · NIGMS · WEST VIRGINIA UNIVERSITY · PI BLANK, AHARON, DRIESSCHAERT, BENOIT · 2022 to 2023
$387k
Biocompatible Magnetic Resonance Probes for in vivo Concurrent Profiling of Interstitial Oxygenation, Acidosis and Inorganic Phosphate: Preclinical Application to CancerK99EB023990 · NIBIB · WEST VIRGINIA UNIVERSITY · PI DRIESSCHAERT, BENOIT · 2017 to 2018
$153k
NCI NIH HHS R01 CA192064NCI NIH HHS R01 CA194013NIBIB NIH HHS K99 EB023990NIBIB NIH HHS R00 EB023990NIBIB NIH HHS R01 EB032321NIBIB NIH HHS R21 EB028553NIGMS NIH HHS R21 GM143595
6 · The paper itself

Abstract

The viscosity measurements are of clinical significance for evaluation of the potential pathological conditions of biological lubricants such as synovial fluids of joints, and for formulation and characterization of peptide- and protein-based biotherapeutics. Due to inherent potential therapeutic activity, protein drugs have proven to be one of the most efficient therapeutic agents in treatment of several life-threatening disorders, such as diabetes and autoimmune diseases. However, home-use applications for treating chronic inflammatory diseases, such as diabetes and rheumatoid arthritis, necessitate the development of high-concentration insulin and monoclonal antibodies formulations for patient self-administration. High protein concentrations can affect viscosity of the corresponding drug solutions complicating their manufacture and administration. The measurements of the viscosity of new insulin analogs and monoclonal antibodies solutions under development is of practical importance to avoid unwanted highly viscous, and therefore, painful for injection drug formulations. Recently, we have demonstrated capability of the electron paramagnetic resonance (EPR) viscometry using viscosity-sensitive

Identifiers

PMID38707765
PMCPMC11068027

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.