Evidence map›Paper›PMID 38707552›Full record

ReviewJSES international2024

Three-dimensional corrective osteotomy for cubitus varus deformity using patient-matched instruments.

Kunihiro Oka, Satoshi Miyamura, Ryoya Shiode, Arisa Kazui, Toru Iwahashi, Hiroyuki Tanaka, Tsuyoshi Murase

Abstract readReview
In one paragraph

Review in JSES international, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed.

  1. Review
  2. Article
  3. Review
  4. Article
  5. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Kunihiro OkaDepartment of Orthopaedic Biomaterial Science, Graduate School of Medicine, Osaka University, Suita, Osaka, Japan.
Satoshi MiyamuraDepartment of Orthopaedic Surgery, Graduate School of Medicine, Osaka University, Suita, Osaka, Japan.
Ryoya ShiodeDepartment of Orthopaedic Surgery, Graduate School of Medicine, Osaka University, Suita, Osaka, Japan.
Arisa KazuiDepartment of Orthopaedic Surgery, Graduate School of Medicine, Osaka University, Suita, Osaka, Japan.
Toru IwahashiDepartment of Orthopaedic Surgery, Graduate School of Medicine, Osaka University, Suita, Osaka, Japan.
Hiroyuki TanakaDepartment of Orthopaedic Surgery, Graduate School of Medicine, Osaka University, Suita, Osaka, Japan.
Tsuyoshi MuraseDepartment of Orthopaedic Surgery, Bellland General Hospital, Sakai, Osaka, Japan.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: Various methods of two or three-dimensional (3D) corrective osteotomy for cubitus varus deformity have been reported. However, whether 3D correction of cubitus varus deformity is necessary is controversial because of technical difficulties and surgical complications. This study introduced 3D simulations and printing technology for corrective osteotomy against cubitus varus deformities. Moreover, recent studies on the application of these technologies were reviewed. Methods: The amount of 3D deformity was calculated based on the difference in 3D shape between the affected side and the contralateral normal side. Patient-matched instruments were created to perform the actual surgery as simulated. Further, a 3D corrective osteotomy was performed using patient-matched instruments for cubitus varus deformity in pediatric and adolescent patients. The humerus-elbow-wrist angle, tilting angle, and elbow ranges of motion were evaluated. Results: Humerus-elbow-wrist angle and tilting angle were corrected from -21° to 14° and from 30° to 43°, respectively, in the pediatric patient and from -18° to 10° and from 20° to 40°, respectively, in the adolescent patient. The elbow flexion and extension angles changed from 130° to 140° and from 20° to 10°, respectively, in the pediatric patient and from 120° to 130° and from 15° to 0°, respectively, in the adolescent patient. Conclusion: The 3D computer simulations and the use of patient-matched instruments for cubitus varus deformity are reliable and can facilitate an accurate and safe correction. These technologies can simplify the complexity of 3D surgical procedures and contribute to the standardization of treatment for cubitus varus deformity.

Indexed as

Computer simulationCorrective osteotomyCubitus varus deformityPatient-matched instrumentSurgical guideThree-dimensional printing technology

Identifiers

PMID38707552
PMCPMC11064714

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.