Evidence map›Paper›PMID 38706986›Full record

ArticleAdvanced functional materials2024

Microengineering 3D Collagen Matrices with Tumor-Mimetic Gradients in Fiber Alignment.

Indranil M Joshi, Mehran Mansouri, Adeel Ahmed, Dinindu De Silva, Richard A Simon, Poorya Esmaili, Danielle E Desa, Tresa M Elias, Edward B Brown, Vinay V Abhyankar

Abstract read
In one paragraph

Article in Advanced functional materials, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 9 papers.

0numbers the graph read from it
0cells of the map it votes in
9citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

9 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Review
  5. Mechano-Organ-on-Chip for Cancer Research.International journal of molecular sciences · 2026
    Review
  6. Article
  7. Review
  8. Article
  9. Article
4 · The record

Corrections and comments

5 · Who and what money

Authors and funding

10 authors.

Indranil M JoshiDepartment of Biomedical Engineering, Rochester Institute of Technology, Rochester, NY.
Mehran MansouriDepartment of Biomedical Engineering, Rochester Institute of Technology, Rochester, NY.
Adeel AhmedDepartment of Biomedical Engineering, Rochester Institute of Technology, Rochester, NY.
Dinindu De SilvaDepartment of Biomedical Engineering, Rochester Institute of Technology, Rochester, NY.
Richard A SimonDepartment of Biomedical Engineering, Rochester Institute of Technology, Rochester, NY.
Poorya EsmailiDepartment of Biomedical Engineering, Rochester Institute of Technology, Rochester, NY.
Danielle E DesaDepartment of Biomedical Engineering, University of Rochester, Rochester, NY.
Tresa M EliasDepartment of Biomedical Engineering, University of Rochester, Rochester, NY.
Edward B BrownDepartment of Biomedical Engineering, University of Rochester, Rochester, NY.
Vinay V AbhyankarDepartment of Biomedical Engineering, Rochester Institute of Technology, Rochester, NY.

Funding

Directed Cell Motility Along Gradients in Extracellular Matrix Fiber AlignmentR16GM146687 · NIGMS · ROCHESTER INSTITUTE OF TECHNOLOGY · PI ABHYANKAR, VINAY V · 2022 to 2025
$930k
Electrokinetic lithography: in situ microengineering of anisotropic 3D collagen matricesR21GM143658 · NIGMS · ROCHESTER INSTITUTE OF TECHNOLOGY · PI ABHYANKAR, VINAY V · 2022 to 2023
$407k
NIGMS NIH HHS R16 GM146687NIGMS NIH HHS R21 GM143658
6 · The paper itself

Abstract

Collagen fibers in the 3D tumor microenvironment (TME) exhibit complex alignment landscapes that are critical in directing cell migration through a process called contact guidance. Previous in vitro work studying this phenomenon has focused on quantifying cell responses in uniformly aligned environments. However, the TME also features short-range gradients in fiber alignment that result from cell-induced traction forces. Although the influence of graded biophysical taxis cues is well established, cell responses to physiological alignment gradients remain largely unexplored. In this work, fiber alignment gradients in biopsy samples are characterized and recreated using a new microfluidic biofabrication technique to achieve tunable sub-millimeter to millimeter scale gradients. This study represents the first successful engineering of continuous alignment gradients in soft, natural biomaterials. Migration experiments on graded alignment show that HUVECs exhibit increased directionality, persistence, and speed compared to uniform and unaligned fiber architectures. Similarly, patterned MDA-MB-231 aggregates exhibit biased migration toward increasing fiber alignment, suggesting a role for alignment gradients as a taxis cue. This user-friendly approach, requiring no specialized equipment, is anticipated to offer new insights into the biophysical cues that cells interpret as they traverse the extracellular matrix, with broad applicability in healthy and diseased tissue environments.

Indexed as

biofabricationcollagen fiber alignmentcontact guidancedirectional cell migrationmicrofluidics

Identifiers

PMID38706986
PMCPMC11067715

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.