ArticleInternational journal of hyperthermia : the official journal of European Society for Hyperthermic Oncology, North American Hyperthermia Group2024

Volumetric hyperthermia delivery using the ExAblate Body MR-guided focused ultrasound system.

Kisoo Kim, Pragya Gupta, Kazim Narsinh, Chris J Diederich, Eugene Ozhinsky

Abstract read
In one paragraph

Article in International journal of hyperthermia : the official journal of European Society for Hyperthermic Oncology, North American Hyperthermia Group, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Kisoo KimDepartment of Radiology & Biomedical Imaging, University of CA, San Francisco, CA, USA.ORCID 0000-0001-8387-9476
Pragya GuptaDepartment of Radiation Oncology, University of California, San Francisco, CA, USA.ORCID 0000-0002-9364-5259
Kazim NarsinhDepartment of Radiology & Biomedical Imaging, University of CA, San Francisco, CA, USA.
Chris J DiederichDepartment of Radiation Oncology, University of California, San Francisco, CA, USA.
Eugene OzhinskyDepartment of Radiology & Biomedical Imaging, University of CA, San Francisco, CA, USA.

Funding

Image-guided ultrasound ablation for precision targeting of prostate cancerR01CA230323 · NCI · ACOUSTIC MEDSYSTEMS, INC. · PI BURDETTE, EVERETTE C, DIEDERICH, CHRIS JOHN · 2018 to 2022
$3.0M
Development of Methods for Precise MR-guided Hyperthermia Delivery for Targeted Cancer TherapiesR21EB026018 · NIBIB · UNIVERSITY OF CALIFORNIA, SAN FRANCISCO · PI OZHINSKY, EUGENE · 2019 to 2021
$603k
Advancing Methods for MR-guided Focused Ultrasound Hyperthermia for Head and Neck CancerK99DE032397 · NIDCR · UNIVERSITY OF CALIFORNIA, SAN FRANCISCO · PI KIM, KISOO · 2023 to 2024
$168k
NCI NIH HHS R01 CA230323NIBIB NIH HHS R21 EB026018NIDCR NIH HHS K99 DE032397
6 · The paper itself

Abstract

objectivesTo investigate image-guided volumetric hyperthermia strategies using the ExAblate Body MR-guided focused ultrasound ablation system, involving mechanical transducer movement and sector-vortex beamforming. MATERIALS AND

methodsAcoustic and thermal simulations were performed to investigate volumetric hyperthermia using mechanical transducer movement combined with sector-vortex beamforming, specifically for the ExAblate Body transducer. The system control in the ExAblate Body system was modified to achieve fast transducer movement and MR thermometry-based hyperthermia control, mechanical transducer movements and electronic sector-vortex beamforming were combined to optimize hyperthermia delivery. The experimental validation was performed using a tissue-mimicking phantom.

resultsThe developed simulation framework allowed for a parametric study with varying numbers of heating spots, sonication durations, and transducer movement times to evaluate the hyperthermia characteristics for mechanical transducer movement and sector-vortex beamforming. Hyperthermic patterns involving 2-4 sequential focal spots were analyzed. To demonstrate the feasibility of volumetric hyperthermia in the system, a tissue-mimicking phantom was sonicated with two distinct spots through mechanical transducer movement and sector-vortex beamforming. During hyperthermia, the average values of Tmax, T10, Tavg, T90, and Tmin over 200 s were measured within a circular ROI with a diameter of 10 pixels. These values were found to be 8.6, 7.9, 6.6, 5.2, and 4.5 °C, respectively, compared to the baseline temperature.

conclusionsThis study demonstrated the volumetric hyperthermia capabilities of the ExAblate Body system. The simulation framework developed in this study allowed for the evaluation of hyperthermia characteristics that could be implemented with the ExAblate MRgFUS system.

Indexed as

Hyperthermia, InducedMagnetic Resonance ImagingHigh-Intensity Focused Ultrasound AblationHumansPhantoms, Imagingdrug deliveryExAblate body arrayfocused ultrasoundHyperthermiaMR-guided focused ultrasoundvolumetric heating

Identifiers

PMID38705588
PMCPMC11135290

What OpenQuestion holds

Textmetadata
LicenceTDM