ArticleJournal of applied clinical medical physics2024
Characterization of a novel pulse normalization technology for beam scanning of small fields without a reference chamber.
Article in Journal of applied clinical medical physics, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed.
- Characterization of a novel pulse normalization technology for beam scanning of small fields without a reference chamber.Journal of applied clinical medical physics · 2024Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
2 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
purposeA novel pulse normalization technology enabling the acquisition of low noise beam data without the use of a physical reference chamber has recently been commercially released. The purpose of this study was to characterize the use of this technology for beam scanning of small fields required in the commissioning of a stereotactic radiotherapy program.
methodsThree detectors (Edge diode, microDiamond, PinPoint) were used to acquire beam data under three conditions: with a reference chamber, with pulse normalization and no reference chamber (PN), and without pulse normalization and no reference chamber (nPN). Percent depth dose (PDD) scans were acquired for 0.5, 1.0, 2.0, and 3.0 cm
resultsAverage 95th percentile CoV values were similar for all detectors across conditions, with PN data being comparable to reference data and minor increases observed for nPN data. Mean gamma pass rates for PN PDD scans exceeded 98% for all detectors. Profile gamma pass rates were 100% for all detectors at 1.4 and 10 cm depth. At 30 cm depth, profiles acquired with the PinPoint and microDiamond detectors had lower mean gamma pass rates than the Edge, at 95% and 95.7%, respectively.
conclusionsA novel pulse normalization technology was demonstrated to be effective for acquiring beam profiles and PDDs for small fields without the use of a physical reference chamber. Limitations in how the method is implemented led to some errors in data acquired using lower sensitivity detectors. When used with a diode, pulse normalization produced equivalent scans to those acquired with a reference chamber.