Evidence map›Paper›PMID 38696675›Full record

ArticleEuropace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology2024

Dual energy for pulmonary vein isolation using dual-energy focal ablation technology integrated with a three-dimensional mapping system: SmartfIRE 3-month results.

Mattias Duytschaever, Gediminas Račkauskas, Tom De Potter, Jim Hansen, Sebastian Knecht, Thomas Phlips, Johan Vijgen, Daniel Scherr, Gabor Szeplaki, Hugo Van Herendael and 4 more

Registry-linked trialAbstract readMulticenter Study
In one paragraph

Article in Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. It is linked to trial NCT05752487 (Safety and Effectiveness Evaluation of the THERMOCOOL SMARTTOUCH SF Catheter With the TRUPULSE Generator for Treatment of Paroxysmal Atrial Fibrillation), which is not on this map. Cited by 16 papers.

0numbers the graph read from it
0cells of the map it votes in
16citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

NCT05752487 nacompletednot on this map

Safety and Effectiveness Evaluation of the THERMOCOOL SMARTTOUCH SF Catheter With the TRUPULSE Generator for Treatment of Paroxysmal Atrial Fibrillation (PAF)

TypeinterventionalSponsorBiosense Webster, Inc.Ran2023 to 2024Enrolled149ConditionsAtrial FibrillationArmsPulsed Field (PF) /Radiofrequency (RF) Catheter ablation
3 · Its place in the literature

Who cites it

16 citing papers in PubMed.

  1. Safety and effectiveness of the TactiFlex duo system: 6-month results of the FOCALFLEX study.Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology · 2026
    Trial
  2. Acute efficacy of a focal dual-energy contact force-sensing catheter vs. standard radiofrequency for anatomical ablation of persistent atrial fibrillation: a pilot study.Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology · 2026
    Article
  3. Review
  4. Review
  5. Latest Advances and Ongoing Challenges in Pulsed Field Ablation.Arrhythmia & electrophysiology review · 2026
    Review
  6. Review
  7. Review
  8. Review
  9. Article
  10. Review
  11. Dual energy for pulmonary vein isolation using focal ablation technology integrated with a three-dimensional mapping system: SmartfIRE 12-month results.Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology · 2025
    Article
  12. Article
  13. Review
  14. Article
  15. Review
  16. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

14 authors.

Mattias DuytschaeverAZ Sint-Jan Hospital, Ruddershove 10, 8000 Bruges, Belgium.ORCID 0000-0001-8451-0013
Gediminas RačkauskasVilnius University Hospital, Santaros Klinikos, Vilnius University, Vilnius, Lithuania.ORCID 0000-0003-3272-4380
Tom De PotterOLV Hospital, Aalst, Belgium.ORCID 0000-0003-1424-114X
Jim HansenGentofte Hospital, University of Copenhagen, Gentofte, Denmark.ORCID 0000-0001-6600-9006
Sebastian KnechtAZ Sint-Jan Hospital, Ruddershove 10, 8000 Bruges, Belgium.ORCID 0000-0003-4500-0146
Thomas PhlipsJessa Hospitals, Hasselt, Belgium.ORCID 0000-0002-4303-9226
Johan VijgenJessa Hospitals, Hasselt, Belgium.ORCID 0000-0003-4928-4836
Daniel ScherrMedical University Graz, Graz, Austria.ORCID 0000-0001-5868-5493
Gabor SzeplakiHeart and Vascular Centre, Mater Private Hospital, Dublin, Ireland.ORCID 0000-0003-3795-1240
Hugo Van HerendaelZiekenhuis Oost-Limburg, Genk, Belgium.ORCID 0000-0001-9603-2370
Mads Brix KronborgAarhus University Hospital, Aarhus, Denmark.ORCID 0000-0003-1672-222X
Benjamin BerteHirslanden St Anna, Lucerne, Switzerland.ORCID 0000-0002-2224-7448
Helmut PürerfellnerOrdensklinikum Linz Elisabethinen, Linz, Austria.ORCID 0000-0002-8965-8495
Peter LukacAarhus University Hospital, Aarhus, Denmark.ORCID 0000-0003-4584-6184

Funding

Biosense Webster, Inc
6 · The paper itself

Abstract

aimsContact force (CF)-sensing radiofrequency (RF) catheters with an ablation index have shown reproducible outcomes for the treatment of atrial fibrillation (AF) in large multicentre studies. A dual-energy (DE) focal CF catheter to deliver RF and unipolar/biphasic pulsed field ablation (PFA), integrated with a three-dimensional (3D) mapping system, can provide operators with additional flexibility. The SmartfIRE study assessed the safety and efficacy of this novel technology for the treatment of drug-refractory, symptomatic paroxysmal AF. Results at 3 months post-ablation are presented here. METHODS AND

resultsPulmonary vein isolation (PVI) was performed using a DE focal, irrigated CF-sensing catheter with the recommendation of PFA at posterior/inferior and RF ablation at the anterior/ridge/carina segments. Irrespective of energy, a tag size of 3 mm; an inter-tag distance ≤6 mm; a target index of 550 for anterior, roof, ridge, and carina; and a target index of 400 for posterior and inferior were recommended. Cavotricuspid isthmus ablation was permitted in patients with documented typical atrial flutter. The primary effectiveness endpoint was acute procedural success. The primary safety endpoint was the rate of primary adverse events (PAEs) within 7 days of the procedure. A prespecified patient subset underwent oesophageal endoscopy (EE; 72 h post-procedure), neurological assessment (NA; pre-procedure and discharge), and cardiac computed tomography (CT)/magnetic resonance angiogram (MRA) imaging (pre-procedure and 3 months post-procedure) for additional safety evaluation, and a mandatory remapping procedure (Day 75 ± 15) for PVI durability assessment. Of 149 patients enrolled between February and June 2023, 140 had the study catheter inserted (safety analysis set) and 137 had ablation energy delivered (per-protocol analysis set). The median (Q1/Q3) total procedure and fluoroscopy times were 108.0 (91.0/126.0) and 4.2 (2.3/7.7) min (n = 137). The acute procedural success rate was 100%. First-pass isolation was achieved in 89.1% of patients and 96.8% of veins. Cavotricuspid isthmus ablations were successfully performed in 12 patients [pulsed field (PF) only: 6, RF only: 5, and RF/PF: 1]. The PAE rate was 4.4% [6/137 patients; 2 pulmonary vein (PV) stenoses, 2 cardiac tamponades/perforations, 1 stroke, and 1 pericarditis]. No coronary artery spasm was reported. No oesophageal lesion was seen in the EE subset (0/31, 0%). In the NA subset (n = 30), microemboli lesions were identified in 2 patients (2/30, 6.7%), both of which were resolved at follow-up; only 1 was symptomatic (silent cerebral lesion, 3.3%). In the CT/MRA subset (n = 30), severe PV narrowing (of >70%) was detected in 2 patients (2/30, 6.7%; vein level 2/128, 1.6%), of whom 1 underwent dilatation and stenting and 1 was asymptomatic; both were associated with high index values and a small inter-tag distance. In the PV durability subset (n = 30), 100/115 treated PVs (87%) were durably isolated and 18/30 patients (60.0%) had all PVs durably isolated.

conclusionA DE focal CF catheter with 3D mapping integration showed a 100% acute success rate with an acceptable safety profile in the treatment of paroxysmal AF. Prespecified 3-month remapping showed notable PVI durability. CLINICAL

trial registrationClinicalTrials.gov Identifier: NCT05752487.

Indexed as

Atrial FibrillationCatheter AblationPulmonary VeinsAgedCardiac CathetersEquipment DesignFemaleHumansImaging, Three-DimensionalMaleMiddle AgedProspective StudiesRecurrenceTime FactorsTreatment OutcomeContact force catheterDual energyFocal catheterPulmonary vein isolationPulsed field ablationVISITAG SURPOINT