Evidence map›Paper›PMID 38696086›Full record

ArticleRadiological physics and technology2024

A deep-learning-based scatter correction with water equivalent path length map for digital radiography.

Masayuki Hattori, Hisato Tsubakiya, Sung-Hyun Lee, Takayuki Kanai, Koji Suzuki, Tetsuya Yuasa

Abstract read
PubMed Publisher
In one paragraph

Article in Radiological physics and technology, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Masayuki HattoriGraduate School of Science and Engineering, Yamagata University, Yonezawa, 992-8510, Japan. m-hattori@med.id.yamagata-u.ac.jp.ORCID http://orcid.org/0009-0008-7725-1744
Hisato TsubakiyaGraduate School of Science and Engineering, Yamagata University, Yonezawa, 992-8510, Japan.
Sung-Hyun LeeDepartment of Heavy Particle Medical Science, Graduate School of Medicine, Yamagata University, Yamagata, 990-9585, Japan.
Takayuki KanaiDepartment of Heavy Particle Medical Science, Graduate School of Medicine, Yamagata University, Yamagata, 990-9585, Japan.
Koji SuzukiDepartment of Radiology, Yamagata University Hospital, Yamagata, 990-9585, Japan.
Tetsuya YuasaGraduate School of Science and Engineering, Yamagata University, Yonezawa, 992-8510, Japan.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

We proposed a new deep learning (DL) model for accurate scatter correction in digital radiography. The proposed network featured a pixel-wise water equivalent path length (WEPL) map of subjects with diverse sizes and 3D inner structures. The proposed U-Net model comprises two concatenated modules: one for generating a WEPL map and the other for predicting scatter using the WEPL map as auxiliary information. First, 3D CT images were used as numerical phantoms for training and validation, generating observed and scattered images by Monte Carlo simulation, and WEPL maps using Siddon's algorithm. Then, we optimised the model without overfitting. Next, we validated the proposed model's performance by comparing it with other DL models. The proposed model obtained scatter-corrected images with a peak signal-to-noise ratio of 44.24 ± 2.89 dB and a structural similarity index measure of 0.9987 ± 0.0004, which were higher than other DL models. Finally, scatter fractions (SFs) were compared with other DL models using an actual phantom to confirm practicality. Among DL models, the proposed model showed the smallest deviation from measured SF values. Furthermore, using an actual radiograph containing an acrylic object, the contrast-to-noise ratio (CNR) of the proposed model and the anti-scatter grid were compared. The CNR of the images corrected using the proposed model are 16% and 82% higher than those of the raw and grid-applied images, respectively. The advantage of the proposed method is that no actual radiography system is required for collecting training dataset, as the dataset is created from CT images using Monte Carlo simulation.

Indexed as

Deep LearningPhantoms, ImagingRadiographic Image EnhancementScattering, RadiationWaterAlgorithmsHumansImage Processing, Computer-AssistedImaging, Three-DimensionalMonte Carlo MethodSignal-To-Noise RatioTomography, X-Ray ComputedWaterDeep learningDigital radiographyMonte Carlo simulationScatter correctionU-NetWater equivalent path length

Identifiers

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.