Evidence map›Paper›PMID 38694829›Full record

ArticleUltrasound (Leeds, England)2024

The reliability of clinical tools with and without ultrasound guidance to measure leg-length inequality.

Richard Cahanin, Andre Fallavollita, Troy Burley, Samuel McQuiston

Open access · greenAbstract read
In one paragraph

Article in Ultrasound (Leeds, England), 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact, top 76% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed, 0 citations in OpenAlex.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors at 1 institution in 1 country.

Richard CahaninDepartment of Physical Therapy, University of South Alabama, Mobile, AL, USA.ORCID https://orcid.org/0000-0001-7816-3406
Andre FallavollitaDepartment of Radiology, University of South Alabama, Mobile, AL, USA.
Troy BurleyDepartment of Physical Therapy, University of South Alabama, Mobile, AL, USA.
Samuel McQuistonDepartment of Radiology, University of South Alabama, Mobile, AL, USA.
University of South Alabama · US

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Purpose: To determine and compare the reliability and efficiency of various methods of leg-length measurement. Methods: A total of 88 leg-lengths were measured among 50 subjects (79%-84% female, mean age = 30-33 years). Leg-lengths were measured in both supine and standing positions using multiple devices, including a tape measure, a LASER distance meter, and diagnostic ultrasound. Results: All methods of leg-length measurement using the middle of the femoral head as a reference point, identified via ultrasound, demonstrated excellent reliability (intraclass correlation coefficient = 0.95-1.00). Measurements performed in supine, using the anterior superior iliac spine as a reference point, with a tape measure, demonstrated good-to-excellent reliability (intraclass correlation coefficient = 0.86-0.95, standard error of the measurement = 16.1-19.9 cm). Standing measurements using the anterior superior iliac spine as a reference point, using a tape measure, demonstrated fair-to-excellent reliability (intraclass correlation coefficient = 0.71-0.95). Conclusion: Ultrasound-guided landmark identification appear to be a more reliable method compared to palpation of the anterior superior iliac spine for measurement of leg-length using clinical tools. When coupled with ultrasound guidance, a hand-held LASER distance meter/pitch locator apparatus or a retractable tape measure appears to be acceptable alternatives to a fixed LASER distance meter on a linear actuator for leg-length measurement.

Indexed as

imaging modalityLASERmusculoskeletaltape measureUltrasound

Identifiers

PMID38694829
PMCPMC11060123
OpenAlexW4387140786

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.