ArticleUltrasound (Leeds, England)2024

Does matrix transducer technology improve quality and repeatability of four-dimensional tricuspid annular plane systolic excursion and mitral annular plane systolic excursion measurements?

Samantha Thomas, Anna Erenbourg, Melissa Chang, Ana Gomes de Melo Tavares Ferreira, Gordon Stevenson, Alec Welsh

Open access · greenAbstract read
In one paragraph

Article in Ultrasound (Leeds, England), 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
0.8field-weighted citation impact, top 30% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed, 2 citations in OpenAlex.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 1 institution in 1 country.

Samantha ThomasSchool of Clinical Medicine, Discipline of Women's Health, Faculty of Medicine, University of New South Wales, Sydney, NSW, Australia.ORCID https://orcid.org/0000-0001-9453-1790
Anna ErenbourgSchool of Clinical Medicine, Discipline of Women's Health, Faculty of Medicine, University of New South Wales, Sydney, NSW, Australia.
Melissa ChangSchool of Clinical Medicine, Discipline of Women's Health, Faculty of Medicine, University of New South Wales, Sydney, NSW, Australia.
Ana Gomes de Melo Tavares FerreiraSchool of Clinical Medicine, Discipline of Women's Health, Faculty of Medicine, University of New South Wales, Sydney, NSW, Australia.
Gordon StevensonSchool of Clinical Medicine, Discipline of Women's Health, Faculty of Medicine, University of New South Wales, Sydney, NSW, Australia.
Alec WelshSchool of Clinical Medicine, Discipline of Women's Health, Faculty of Medicine, University of New South Wales, Sydney, NSW, Australia.
The University of Sydney · AU

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: Novel ultrasound technology and software processing allow offline evaluation of tricuspid annular plane systolic excursion and mitral annular plane systolic excursion measurements. We wished to compare both novel 4D matrix (eM6C) and conventional (RAB6-D) transducers with variable settings (electronic spatiotemporal image correlation, spatiotemporal image correlation and four-dimensional real time) to determine if there was a significant difference in absolute value, quality and repeatability of the resultant reconstructed image and M-mode trace. Methods: A blinded prospective cross-sectional study of normal fetuses from 23 to 38 weeks' gestation were recruited. After routine sonography, four-dimensional volumes were stored and analysed using GE 4DView™ software. Statistical analysis explored variability, correlations and repeatability of the measurements with chi-square analysis, intraclass correlations and the Bland-Altman comparison plots. A scoring system was devised for image quality. Results: Eighteen participants generated 282 data volumes. Absolute values demonstrated some inconsistencies for both tricuspid annular plane systolic excursion and mitral annular plane systolic excursion measurements with variations between transducers: the highest for the RAB6-D/spatiotemporal image correlation setting and the lowest for the four-dimensional real-time settings. The RAB6-D/spatiotemporal image correlation setting was the most repeatable combination (intraclass correlation coefficient = 0.85). Poorest image quality (M-mode trace, four-chamber view, annuli) came from the RAB6-D/four-dimensional real-time combination with the eM6C/electronic spatiotemporal image correlation and RAB6-D/spatiotemporal image correlation settings being nearly identical. Conclusion: We show that transducer and setting combinations influence absolute tricuspid annular plane systolic excursion/mitral annular plane systolic excursion measurements, so need to be articulated in future research. The transducer setting (electronic spatiotemporal image correlation/spatiotemporal image correlation/four-dimensional real time) was a more significant factor than the type of transducer (conventional vs matrix). Subjective image evaluation does not correlate well with repeatability of image acquisition. Further studies are needed to compare measurements using four-dimensional post-processing tools against conventional real-time measurements.

Indexed as

electronic spatiotemporal image correlationfetal heartfour-dimensional matrixmitral annular plane systolic excursion (MAPSE)spatiotemporal image correlationTricuspid annular plane systolic excursion (TAPSE)

Identifiers

PMID38694827
PMCPMC11060120
OpenAlexW4390698374

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.