Evidence map›Paper›PMID 38692250›Full record

ArticleJournal of magnetic resonance (San Diego, Calif. : 1997)2024

Surface dielectric resonator for in vivo EPR measurements.

Sergey V Petryakov, Maciej M Kmiec, Conner S Ubert, Victor B Kassey, Philip E Schaner, Periannan Kuppusamy

Abstract read
In one paragraph

Article in Journal of magnetic resonance (San Diego, Calif. : 1997), 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed.

  1. Article
  2. Article
  3. OxyTrack: A Novel Needle Sensor for In Situ Oximetry.Magnetic resonance in medicine · 2026
    Article
  4. Article
  5. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Sergey V PetryakovDepartment of Radiology, Geisel School of Medicine at Dartmouth, Hanover, NH, USA.
Maciej M KmiecDepartment of Radiology, Geisel School of Medicine at Dartmouth, Hanover, NH, USA.
Conner S UbertDepartment of Radiology, Geisel School of Medicine at Dartmouth, Hanover, NH, USA; Thayer School of Engineering, Dartmouth College, Hanover, NH, USA.
Victor B KasseyDepartment of Radiology, Geisel School of Medicine at Dartmouth, Hanover, NH, USA.
Philip E SchanerDepartment of Radiation Oncology and Applied Sciences, Geisel School of Medicine at Dartmouth, Hanover, NH, USA.
Periannan KuppusamyDepartment of Radiology, Geisel School of Medicine at Dartmouth, Hanover, NH, USA; Thayer School of Engineering, Dartmouth College, Hanover, NH, USA; Department of Radiation Oncology and Applied Sciences, Geisel School of Medicine at Dartmouth, Hanover, NH, USA. Electronic address: Periannan.Kuppusamy@Dartmouth.edu.

Funding

Translational Engineering in Cancer (TEC)P30CA023108 · NCI · DARTMOUTH COLLEGE · PI Fred W Kolling IV · 1985 to 2026
$91.3M
Probes and Methods for Clinical OximetryR01EB004031 · NIBIB · OHIO STATE UNIVERSITY · PI KUPPUSAMY, PERIANNAN · 2004 to 2021
$7.1M
Multimodal Marker for imaging oximetry in radiotherapyR01CA269234 · NCI · DARTMOUTH COLLEGE · PI PERIANNAN KUPPUSAMY · 2023 to 2026
$3.0M
NCI NIH HHS P30 CA023108NCI NIH HHS R01 CA269234NIBIB NIH HHS R01 EB004031
6 · The paper itself

Abstract

This research report describes a novel surface dielectric resonator (SDR) with a flexible connector for in vivo electron paramagnetic resonance (EPR) spectroscopy. Contrary to the conventional cavity or surface loop-gap resonators, the newly developed SDR is constructed from a ceramic dielectric material, and it is tuned to operate at the L-band frequency band (1.15 GHz) in continuous-wave mode. The SDR is designed to be critically coupled and capable of working with both very lossy samples, such as biological tissues, and non-lossy materials. The SDR was characterized using electromagnetic field simulations, assessed for sensitivity with a B

Indexed as

Electromagnetic FieldsEquipment DesignPhantoms, ImagingElectron Spin Resonance SpectroscopyOximetryReproducibility of Results

Identifiers

PMID38692250
PMCPMC11102834

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked