Evidence map›Paper›PMID 38691735›Full record

ArticleOptics letters2024

Time-gated single-pixel imaging of Cherenkov emission from a medical linear accelerator.

Mengyu Jia, Zhaoqi Wei, Feng Gao, Mingfeng Jiang, Wei Wang, Zhiyong Yuan, Brian W Pogue

Abstract read
In one paragraph

Article in Optics letters, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Mengyu Jia
Zhaoqi Wei
Feng Gao
Mingfeng Jiang
Wei Wang
Zhiyong Yuan
Brian W Pogue

Funding

OPTICAL CHERENKOV IMAGING DOSIMETRY IN HUMAN RADIOTHERAPYR01EB023909 · NIBIB · UNIVERSITY OF WISCONSIN-MADISON · PI GLADSTONE, DAVID J., JARVIS, LESLEY A · 2017 to 2024
$4.4M
NIBIB NIH HHS R01 EB023909
6 · The paper itself

Abstract

Cherenkov imaging is an ideal tool for real-time in vivo verification of a radiation therapy dose. Given that radiation is pulsed from a medical linear accelerator (LINAC) together with weak Cherenkov emissions, time-gated high-sensitivity imaging is required for robust measurements. Instead of using an expensive camera system with limited efficiency of detection in each pixel, a single-pixel imaging (SPI) approach that maintains promising sensitivity over the entire spectral band could be used to provide a low-cost and viable alternative. A prototype SPI system was developed and demonstrated here in Cherenkov imaging of LINAC dose delivery to a water tank. Validation experiments were performed using four regular fields and an intensity-modulated radiotherapy (IMRT) delivery plan. The Cherenkov image-based projection percent depth dose curves (pPDDs) were compared to pPDDs simulated by the treatment planning system (TPS), with an overall average error of 0.48, 0.42, 0.65, and 1.08% for the 3, 5, 7, and 9 cm square beams, respectively. The composite image of the IMRT plan achieved a 85.9% pass rate using 3%/3 mm gamma index criteria, in comparing Cherenkov intensity and TPS dose. This study validates the feasibility of applying SPI to the Cherenkov imaging of radiotherapy dose for the first time to our knowledge.

Indexed as

Particle AcceleratorsRadiotherapy DosageRadiotherapy, Intensity-ModulatedTime Factors