ArticleJTCVS open2024
A modified intraventricular balloon method for functional assessment of hearts from donation after circulatory death.
Article in JTCVS open, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
7 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Objective: Functional assessment of hearts during ex-vivo heart perfusion is not well-established. Conventional intraventricular balloon methods for large animals sacrifice the mitral valve. This study assessed the effectiveness of the modified intraventricular balloon method in comparison with other modalities used during working mode in juvenile pigs. Methods: Following asphyxia circulatory arrest, hearts were ischemic for 15 minutes and then reperfused on an ex-vivo device for 2 hours before switching to working mode. Left ventricular pressure was continuously measured during reperfusion by a saline-filled balloon fixated in the left atrium. Spearman Correlation Coefficients with linear regression lines with confidence intervals were analyzed. Results: Maximum dp/dt at 90 minutes of reperfusion and minimum dp/dt at 60 minutes of reperfusion showed a moderate positive correlation to that in working mode, respectively (Rs = 0.61, Conclusions: Functional parameters of contractility and relaxation measured during reperfusion by the modified balloon method showed significant correlations to respective parameters in working mode. This mitral valve sparing technique can be used to predict viability and ventricular function in the early phase of ex-vivo heart perfusion without loading the heart during working mode.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.