Evidence map›Paper›PMID 38690416›Full record

ArticleJTCVS open2024

Determining optimal air leak resolution criteria when using digital pleural drainage device after lung resection.

Mohsen Alayche, Justen Choueiry, Adnan Mekdachi, Donna E Maziak, Andrew J E Seely, Sudhir R Sundaresan, Patrick J Villeneuve, Daniel Jones, William Klement, Sebastien Gilbert

Open access · goldAbstract read
In one paragraph

Article in JTCVS open, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
–field-weighted citation impact, top 98% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed, 0 citations in OpenAlex.

  1. Article
  2. Review
  3. Review
  4. Article
  5. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors at 1 institution in 1 country.

Mohsen AlaycheDivision of Thoracic Surgery, The Ottawa Hospital, Ottawa, Ontario, Canada.
Justen ChoueiryDivision of Thoracic Surgery, The Ottawa Hospital, Ottawa, Ontario, Canada.
Adnan MekdachiDivision of Thoracic Surgery, The Ottawa Hospital, Ottawa, Ontario, Canada.
Donna E MaziakFaculty of Medicine, University of Ottawa, Ottawa, Ontario, Canada.
Andrew J E SeelyFaculty of Medicine, University of Ottawa, Ottawa, Ontario, Canada.
Sudhir R SundaresanFaculty of Medicine, University of Ottawa, Ottawa, Ontario, Canada.
Patrick J VilleneuveDivision of Thoracic Surgery, The Ottawa Hospital, Ottawa, Ontario, Canada.
Daniel JonesFaculty of Medicine, University of Ottawa, Ottawa, Ontario, Canada.
William KlementFaculty of Medicine, University of Ottawa, Ottawa, Ontario, Canada.
Sebastien GilbertDivision of Thoracic Surgery, The Ottawa Hospital, Ottawa, Ontario, Canada.
University of Ottawa · CA

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Objective: There is limited clinical evidence to support any specific parenchymal air leak resolution criteria when using digital pleural drainage devices following lung resection. The aim of this study is to determine an optimal air leak resolution criteria, where duration of chest tube drainage is minimized while avoiding complications from premature chest tube removal. Methods: Airflow data averaged at 10-minute intervals was collected prospectively using a digital pleural drainage device (Thopaz; Medela) in 400 patients from 2015 to 2019. All permutations of air leak resolution criteria from <10 to 100 mL/minute for 4 to 12 hours were applied retrospectively to the pleural drainage data to determine air leak duration, and air leak recurrence frequency and volume. Air leak recurrence indicates potential for rather than occurrence of adverse events. Descriptive statistics were used to identify the optimal criteria based on patient safety (low frequency and volume of air leak recurrences), and efficiency (shortest initial air leak duration). Results: The majority of the 400 patients underwent lobectomy (57% [227 out of 400]), wedge resections (29% [115 out of 400]), or segmentectomies (8% [32 out of 400]) for lung cancer (90% [360 out of 400]). An airflow threshold <50 mL/minute resulted in longer air leak duration before meeting the criteria for air leak resolution ( Conclusions: When using a digital pleural drainage device, a postoperative air leak resolution criteria <50 mL/minute for 8 consecutive hours was associated with the best safety and efficiency profile.

Indexed as

air leak durationair leak recurrenceair leak resolution criteriachest tube

Identifiers

PMID38690416
PMCPMC11056469
OpenAlexW4391543806

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked