ArticleLa Radiologia medica2024

Photon-counting detector computed tomography for metal artifact reduction: a comparative study of different artifact reduction techniques in patients with orthopedic implants.

Fabian Bernhard Pallasch, Alexander Rau, Marco Reisert, Stephan Rau, Thierno Diallo, Thomas Stein, Sebastian Faby, Fabian Bamberg, Jakob Weiss

Abstract readComparative Study
In one paragraph

Article in La Radiologia medica, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 11 papers.

0numbers the graph read from it
0cells of the map it votes in
11citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

11 citing papers in PubMed.

  1. Article
  2. Review
  3. Article
  4. Review
  5. Review
  6. Article
  7. Article
  8. Review
  9. Review
  10. Article
  11. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors.

Fabian Bernhard PallaschDepartment of Radiology, University Medical Center Freiburg, Hugstetter Str. 55, 79106, Freiburg im Breisgau, Germany. Fabian.pallasch@uniklinik-freiburg.de.ORCID http://orcid.org/0000-0003-2011-0939
Alexander RauDepartment of Radiology, University Medical Center Freiburg, Hugstetter Str. 55, 79106, Freiburg im Breisgau, Germany.
Marco ReisertDepartment of Radiology, University Medical Center Freiburg, Hugstetter Str. 55, 79106, Freiburg im Breisgau, Germany.
Stephan RauDepartment of Radiology, University Medical Center Freiburg, Hugstetter Str. 55, 79106, Freiburg im Breisgau, Germany.
Thierno DialloDepartment of Radiology, University Medical Center Freiburg, Hugstetter Str. 55, 79106, Freiburg im Breisgau, Germany.
Thomas SteinDepartment of Radiology, University Medical Center Freiburg, Hugstetter Str. 55, 79106, Freiburg im Breisgau, Germany.
Sebastian FabySiemens Healthcare GmbH, Siemensstr. 3, 91301, Forchheim, Germany.
Fabian BambergDepartment of Radiology, University Medical Center Freiburg, Hugstetter Str. 55, 79106, Freiburg im Breisgau, Germany.
Jakob WeissDepartment of Radiology, University Medical Center Freiburg, Hugstetter Str. 55, 79106, Freiburg im Breisgau, Germany.

Funding

Ministerium für Wirtschaft, Arbeit und Wohnungsbau Baden-Württemberg 35-4223.10/20
6 · The paper itself

Abstract

purposeArtifacts caused by metallic implants remain a challenge in computed tomography (CT). We investigated the impact of photon-counting detector computed tomography (PCD-CT) for artifact reduction in patients with orthopedic implants with respect to image quality and diagnostic confidence using different artifact reduction approaches. MATERIAL AND

methodsIn this prospective study, consecutive patients with orthopedic implants underwent PCD-CT imaging of the implant area. Four series were reconstructed for each patient (clinical standard reconstruction [PCD-CT

resultsWe enrolled 39 patients with a mean age of 67.3 ± 13.2 years (51%; n = 20 male) and a mean BMI of 26.1 ± 4 kg/m

conclusionPCD-CT allows for effective metal artifact reduction in patients with orthopedic implants, resulting in superior image quality and diagnostic confidence with the potential to improve patient management and clinical decision making.

Indexed as

ArtifactsMetalsTomography, X-Ray ComputedAgedAged, 80 and overFemaleHumansMaleMiddle AgedPhotonsProspective StudiesProstheses and ImplantsRadiographic Image Interpretation, Computer-AssistedMetalsArthroplasty, replacement, hipArtifactsComputer-assistedImage processingMultidetector computed tomographySpine

Identifiers

PMID38689182
PMCPMC11168992