Evidence map›Paper›PMID 38687415›Full record

Observational studyJournal of clinical monitoring and computing2024

Agreement between three noninvasive temperature monitoring devices during spinal anaesthesia for caesarean delivery: a prospective observational study.

D O Vawda, Christopher King, L du Toit, R A Dyer, N J Masuku, D G Bishop

Abstract readObservational StudyComparative Study
In one paragraph

Observational study in Journal of clinical monitoring and computing, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

D O VawdaDepartment of Anaesthesia, School of Clinical Medicine, College of Health Sciences, Grey's Hospital, University of KwaZulu-Natal, Pietermaritzburg, 3201, South Africa.ORCID 0009-0002-6401-0489
Christopher KingDepartment of Anesthesiology, Washington University School of Medicine in St Louis, MO, USA.ORCID 0000-0002-4574-8616
L du ToitDepartment of Anesthesiology, Washington University School of Medicine in St Louis, MO, USA.ORCID 0000-0003-0146-4002
R A DyerDepartment of Anaesthesia and Perioperative Medicine, University of Cape Town, Cape Town, South Africa.ORCID 0000-0002-8165-9098
N J MasukuDepartment of Anaesthesia, School of Clinical Medicine, College of Health Sciences, Grey's Hospital, University of KwaZulu-Natal, Pietermaritzburg, 3201, South Africa.ORCID 0000-0001-6250-2389
D G BishopDepartment of Anaesthesia, School of Clinical Medicine, College of Health Sciences, Grey's Hospital, University of KwaZulu-Natal, Pietermaritzburg, 3201, South Africa. davidgbishop@gmail.com.ORCID 0000-0001-9861-3646

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Hypothermia during obstetric spinal anaesthesia is a common and important problem, yet temperature monitoring is often not performed due to the lack of a suitable, cost-effective monitor. This study aimed to compare a noninvasive core temperature monitor with two readily available peripheral temperature monitors during obstetric spinal anaesthesia. We undertook a prospective observational study including elective and emergency caesarean deliveries, to determine the agreement between affordable reusable surface temperature monitors (Welch Allyn SureTemp® Plus oral thermometer and the Braun 3-in-1 No Touch infrared thermometer) and the Dräger T-core© (using dual-sensor heat flux technology), in detecting thermoregulatory changes during obstetric spinal anaesthesia. Predetermined clinically relevant limits of agreement (LOA) were set at ± 0.5 °C. We included 166 patients in our analysis. Hypothermia (heat flux temperature < 36 °C) occurred in 67% (95% CI 49 to 78%). There was poor agreement between devices. In the Bland-Altman analysis, LOA for the heat flux monitor vs. oral thermometer were 1.8 °C (CI 1.7 to 2.0 °C; bias 0.5 °C), for heat flux monitor vs. infrared thermometer LOA were 2.3 °C (CI 2.1 to 2.4 °C; bias 0.4 °C) and for infrared vs. oral thermometer, LOA were 2.0 °C (CI 1.9 to 2.2 °C; bias 0.1 °C). Error grid analysis highlighted a large amount of clinical disagreement between methods. While monitoring of core temperature during obstetric spinal anaesthesia is clinically important, agreement between monitors was below clinically acceptable limits. Future research with gold-standard temperature monitors and exploration of causes of sensor divergence is needed.

Indexed as

Anesthesia, SpinalBody TemperatureCesarean SectionHypothermiaMonitoring, IntraoperativeThermometersAdultAnesthesia, ObstetricalBody Temperature RegulationFemaleHumansMonitoring, PhysiologicPregnancyProspective StudiesReproducibility of ResultsThermometryCaesarean deliveryHypothermiaObstetric anaesthesiaSpinal anaesthesiaTemperature monitoringThermoregulation

Identifiers

PMID38687415
PMCPMC11427619

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked