ArticleJournal of clinical microbiology2024
Performance characteristics of highly automated HSV-1 and HSV-2 IgG testing.
Article in Journal of clinical microbiology, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
6 citing papers in PubMed.
- Comparative Evaluation of CLIA and ELISA Serological Assays for HSV-1 IgG With Western Blot Confirmation in a Clinical Cohort: A Cross-Sectional Study.Health science reports · 2026Article
- Herpes Simplex Virus Type 1 and Type 2 Western Blot Serology Test Results From 1999 to 2020 in a US Reference Laboratory.Sexually transmitted diseases · 2026Article
- Herpes Simplex Virus Infections: An Overview of Testing for the Urgent Care Clinician.JUCM : the journal of urgent care medicine · 2025Article
- Article
- Control of HSV-1 Infection: Directions for the Development of CRISPR/Cas-Based Therapeutics and Diagnostics.International journal of molecular sciences · 2024Review
- Antibody immune responses and causal relationships in four immune skin diseases: Evidence from Mendelian randomization and Bayesian Weighting (Antibody Responses in Skin Diseases: MR & Bayesian).Skin research and technology : official journal of International Society for Bioengineering and the Skin (ISBS) [and] International Society for Digital Imaging of Skin (ISDIS) [and] International Society for Skin Imaging (ISSI) · 2024Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
8 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Herpes simplex virus (HSV) infections are one of the most common and stigmatized infections of humankind, affecting more than 4 billion people around the world and more than 100 million Americans. Yet, most people do not know their infection status, and antibody testing is not recommended, partly due to poor test performance. Here, we compared the test performance of the Roche Elecsys HSV-1 IgG and HSV-2 IgG, DiaSorin LIAISON HSV-1/2 IgG, and Bio-Rad BioPlex 2200 HSV-1 and HSV-2 IgG assays with the gold-standard HSV western blot in 1,994 persons, including 1,017 persons with PCR or culture-confirmed HSV-1 and/or HSV-2 infection. Across all samples, the Bio-Rad and Roche assays had similar performance metrics with low sensitivity (<85%) but high specificity (>97%) for detecting HSV-1 IgG and both high sensitivity (>97%) and high specificity (>98%) for detecting HSV-2 IgG. The DiaSorin assay had a higher sensitivity (92.1%) but much lower specificity (88.7%) for detecting HSV-1 IgG and comparatively poor sensitivity (94.5%) and specificity (94.2%) for detecting HSV-2 IgG. The DiaSorin assay performed poorly at low-positive index values with 60.9% of DiaSorin HSV-1 results and 20.8% of DiaSorin HSV-2 results with positive index values <3.0 yielding false positive results. Based on an estimated HSV-2 seroprevalence of 12% in the United States, positive predictive values for HSV-2 IgG were 96.1% for Roche, 87.4% for Bio-Rad, and 69.0% for DiaSorin, meaning nearly one of every three positive DiaSorin HSV-2 IgG results would be falsely positive. Further development in HSV antibody diagnostics is needed to provide appropriate patient care.IMPORTANCESerological screening for HSV infections is currently not recommended in part due to the poor performance metrics of widely used commercial HSV-1 and HSV-2 IgG assays. Here, we compare three Food and Drug Administration (FDA)-cleared automated HSV-1 and HSV-2 IgG assays to the gold-standard western blot across nearly 2,000 samples. We find that not all commercially available HSV assays are created equal, with comparably low sensitivities for HSV-1 IgG across platforms and high false positivity rates for DiaSorin on HSV-2 IgG. This study is the first large-scale comparison of performance metrics for the Bio-Rad and Roche assays in over 10 years. Our study confirms that there remains room for improvement in HSV serological diagnostic testing-especially in regard to low sensitivities for HSV-1 IgG detection-and highlights that some previously less-studied assays may have better performance metrics than previously considered typical of commercially available HSV-2 IgG assays.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials