Evidence map›Paper›PMID 38686407›Full record

ArticleSheng wu yi xue gong cheng xue za zhi = Journal of biomedical engineering = Shengwu yixue gongchengxue zazhi2024

[Microwave Heartprint: A novel non-contact human identification technology based on cardiac micro-motion detection using ultra wideband bio-radar].

Wei Huang, Wei Ren, Kehan Wang, Zhao Li, Jianqi Wang, Guohua Lu, Fugui Qi

Abstract readEnglish Abstract
In one paragraph

Article in Sheng wu yi xue gong cheng xue za zhi = Journal of biomedical engineering = Shengwu yixue gongchengxue zazhi, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Wei HuangSchool of Basic Medical Science, Fourth Military Medical University, Xi'an 710032, P. R. China.
Wei RenDepartment of Computing, Hong Kong Polytechnic University, Hong Kong 999077, P. R. China.
Kehan WangSchool of Basic Medical Science, Fourth Military Medical University, Xi'an 710032, P. R. China.
Zhao LiSchool of Biomedical Engineering, Fourth Military Medical University, Xi'an 710032, P. R. China.
Jianqi WangSchool of Biomedical Engineering, Fourth Military Medical University, Xi'an 710032, P. R. China.
Guohua LuSchool of Biomedical Engineering, Fourth Military Medical University, Xi'an 710032, P. R. China.
Fugui QiSchool of Biomedical Engineering, Fourth Military Medical University, Xi'an 710032, P. R. China.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

The existing one-time identity authentication technology cannot continuously guarantee the legitimacy of user identity during the whole human-computer interaction session, and often requires active cooperation of users, which seriously limits the availability. This study proposes a new non-contact identity recognition technology based on cardiac micro-motion detection using ultra wideband (UWB) bio-radar. After the multi-point micro-motion echoes in the range dimension of the human heart surface area were continuously detected by ultra wideband bio-radar, the two-dimensional principal component analysis (2D-PCA) was exploited to extract the compressed features of the two-dimensional image matrix, namely the distance channel-heart beat sampling point (DC-HBP) matrix, in each accurate segmented heart beat cycle for identity recognition. In the practical measurement experiment, based on the proposed multi-range-bin & 2D-PCA feature scheme along with two conventional reference feature schemes, three typical classifiers were selected as representatives to conduct the heart beat identification under two states of normal breathing and breath holding. The results showed that the multi-range-bin & 2D-PCA feature scheme proposed in this paper showed the best recognition effect. Compared with the optimal range-bin & overall heart beat feature scheme, our proposed scheme held an overall average recognition accuracy of 6.16% higher (normal respiration: 6.84%; breath holding: 5.48%). Compared with the multi-distance unit & whole heart beat feature scheme, the overall average accuracy increase was 27.42% (normal respiration: 28.63%; breath holding: 26.21%) for our proposed scheme. This study is expected to provide a new method of undisturbed, all-weather, non-contact and continuous identification for authentication.

Indexed as

HeartPrincipal Component AnalysisAlgorithmsBiometric IdentificationHeart RateHumansMotionRespirationSignal Processing, Computer-AssistedBio-radarHeart micro-motionHuman identificationMicrowave heartprintNon-contact

Identifiers

PMID38686407
PMCPMC11058502

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.