Evidence map›Paper›PMID 38682921›Full record

ArticleJournal of visualized experiments : JoVE2024

Development of a Low-cost Epimysial Electromyography Electrode: A Simplified Workflow for Fabrication and Testing.

Luke Stoneback, Genaro D Fullano, McKenzie S White, Sairub Naaz, Lindsey K Lepley

Abstract readVideo-Audio Media
In one paragraph

Article in Journal of visualized experiments : JoVE, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Luke Stoneback *School of Kinesiology, University of Michigan, Ann Arbor; lukeston@umich.edu.
Genaro D Fullano *University of Michigan Medical School.
McKenzie S WhiteSchool of Kinesiology, University of Michigan, Ann Arbor.
Sairub NaazSchool of Kinesiology, University of Michigan, Ann Arbor.
Lindsey K LepleySchool of Kinesiology, University of Michigan, Ann Arbor; llepley@umich.edu.

Funding

Translational strategies for optimizing musculoskeletal recovery after ACL injuryR01AR081235 · NIAMS · UNIVERSITY OF MICHIGAN AT ANN ARBOR · PI LEPLEY, LINDSEY K · 2022 to 2025
$1.8M
NIAMS NIH HHS R01 AR081235
6 · The paper itself

Abstract

Electromyography (EMG) is a valuable diagnostic tool for detecting neuromuscular abnormalities. Implantable epimysial electrodes are commonly used to measure EMG signals in preclinical models. Although classical resources exist describing the principles of epimysial electrode fabrication, there is a sparsity of illustrative information translating electrode theory to practice. To remedy this, we provide an updated, easy-to-follow guide on fabricating and testing a low-cost epimysial electrode. Electrodes were made by folding and inserting two platinum-iridium foils into a precut silicone base to form the contact surfaces. Next, coated stainless steel wires were welded to each contact surface to form the electrode leads. Lastly, a silicone mixture was used to seal the electrode. Ex vivo testing was conducted to compare our custom-fabricated electrode to an industry standard electrode in a saline bath, where high levels of signal agreement (sine [intraclass correlation - ICC= 0.993], square [ICC = 0.995], triangle [ICC = 0.958]), and temporal-synchrony (sine [r = 0.987], square [r = 0.990], triangle [r= 0.931]) were found across all waveforms. Low levels of electrode impedance were also quantified via electrochemical impedance spectroscopy. An in vivo performance assessment was also conducted where the vastus lateralis muscle of a rat was surgically instrumented with the custom-fabricated electrode and signaling was acquired during uphill and downhill walking. As expected, peak EMG activity was significantly lower during downhill walking (0.008 ± 0.005 mV) than uphill (0.031 ± 0.180 mV, p = 0.005), supporting the validity of the device. The reliability and biocompatibility of the device were also supported by consistent signaling during level walking at 14 days and 56 days post implantation (0.01 ± 0.007 mV, 0.012 ± 0.007 mV respectively; p > 0.05) and the absence of histological inflammation. Collectively, we provide an updated workflow for the fabrication and testing of low-cost epimysial electrodes.

Indexed as

Electrodes, ImplantedElectromyographyAnimalsElectrodesEquipment DesignMuscle, SkeletalRatsWorkflow

Identifiers

PMID38682921
PMCPMC11995407

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.