SynthesisThe Cochrane database of systematic reviews2024
Autologous platelet-rich plasma for assisted reproduction.
Synthesis in The Cochrane database of systematic reviews, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 28 papers, 5 of them syntheses that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
28 citing papers in PubMed, 5 syntheses or guidelines pooled it.
- Role of platelet-rich plasma in unexplained recurrent implantation failure: an umbrella review.Frontiers in reproductive health · 2026Pooled it
- The role and implication of platelet-rich plasma in male factor infertility: A systematic review of human studies.Andrology · 2026Pooled it
- Is sub-endometrial injection a superior method for the administration of intrauterine PRP?: a systematic review and meta-analysis.Reproductive biology and endocrinology : RB&E · 2025Pooled it
- Autologous platelet-rich plasma for assisted reproduction.The Cochrane database of systematic reviews · 2024Pooled it
- Platelet rich plasma for assisted reproduction: an overview of systematic reviews.Blood transfusion = Trasfusione del sanguePooled it
- Intrauterine platelet-rich plasma infusion for recurrent implantation failure: a pilot randomized controlled single-blinded clinical trial in the USA.Journal of assisted reproduction and genetics · 2026Trial
- Effect of acupuncture for poor ovarian response: a multicenter randomized controlled trial.Frontiers in endocrinology · 2026Trial
- Article
- Bilateral ovarian abscesses following platelet-rich plasma injection for "ovarian rejuvenation": a case report.F&S reports · 2026Article
- Progress in research on the effects of Platelet-Rich Plasma (PRP) ovarian injection on early ovarian reserve dysfunction and premature ovarian insufficiency.Journal of ovarian research · 2026Review
- Special Issue "Current Trends and Future Challenges in Assisted Reproduction".Journal of personalized medicine · 2026Article
- Impact of intrauterine infusion of human umbilical cord blood mononuclear cells on reproductive outcomes in patients with thin endometrium undergoing frozen embryo transfer.Frontiers in cell and developmental biology · 2026Article
- Multidimensional regulatory architecture of endometrial receptivity and its translational implications for implantation failure.Frontiers in endocrinology · 2026Review
- Platelet-rich plasma in reproductive medicine: from ovarian follicles to the ovarian niche and emerging stem cell mobilization-based regenerative strategies.Frontiers in reproductive health · 2026Review
- Endometrial receptivity failure in assisted reproduction: immune-cellular niches, mechanistic evidence, and translational boundaries.Frontiers in immunology · 2026Review
- Article
- Article
- Extracellular matrix dysregulation in PCOS: pathogenesis, therapeutic strategies, and innovative technologies.Journal of biological engineering · 2025Review
- Is it justified to offer intrauterine infusion of autologous PRP in women with repeated implantation failure?Human reproduction (Oxford, England) · 2025Review
- Comprehensive single-cell transcriptome analysis of autologous platelet-rich plasma therapy on human thin endometrium.Scientific reports · 2025Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
3 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundAutologous platelet-rich plasma (PRP) consists of plasma and a concentrate of platelets extracted from fresh whole blood of the person being treated. Research has suggested that intrauterine or intraovarian infusion/injection of PRP before embryo transfer may improve endometrial receptivity and response to ovarian stimulation in women undergoing assisted reproduction. We compared these interventions to standard treatment, placebo, or other interventions (mechanical or pharmacological).
objectivesTo assess the effectiveness and safety of intrauterine and intraovarian infusion/injection of platelet-rich plasma in infertile women undergoing assisted reproductive technology cycles. SEARCH
methodsWe searched the Cochrane Gynaecology and Fertility Group's Specialised Register, CENTRAL, MEDLINE, Embase, and the Epistemonikos database in January 2023. We also searched the reference lists of relevant articles and contacted the trial authors and experts in the field for any additional trials. SELECTION CRITERIA: We included randomized controlled trials (RCTs) that evaluated the application of PRP in the uterine cavity, ovaries, or both versus no intervention, placebo, or any other intervention (either mechanical or pharmacological) in women undergoing in vitro fertilization (IVF) or intracytoplasmic sperm injection (ICSI) cycles. DATA COLLECTION AND ANALYSIS: We followed standard methodological procedures recommended by Cochrane, including use of the updated risk of bias tool (RoB 2). The primary outcomes were live birth (or ongoing pregnancy) and miscarriage. The secondary outcomes were clinical pregnancy, complications of the procedure, multiple pregnancy, ectopic pregnancy, fetal growth restriction, preterm delivery, and fetal abnormality. We estimated the average effect of the interventions by fitting a Der Simonian-Laird's random-effects meta-analysis model. We reported pooled odds ratios (ORs) with 95% confidence intervals (CIs). We restricted the primary analyses to trials at low risk of bias for the outcomes and performed sensitivity analyses that included all studies. MAIN
resultsWe included 12 parallel-group RCTs that recruited a total of 1069 women. We identified three different comparison groups. Using GRADE, we assessed the certainty of evidence as very low for almost all outcomes. Intrauterine injection/infusion of platelet-rich plasma versus no intervention or placebo Nine studies evaluated intrauterine PRP versus no intervention or placebo. Eight included women with at least two or three previous implantation failures. Only one was assessed at low risk of bias for each outcome. This study provided very low-certainty evidence about the effect of intrauterine PRP injection versus no intervention on live birth (OR 1.10, 95% CI 0.38 to 3.14; 94 women) and miscarriage (OR 0.96, 95% CI 0.13 to 7.09; 94 women). If the likelihood of live birth following no intervention is assumed to be 17%, then the likelihood following intrauterine PRP would be 7% to 40%; and if the risk of miscarriage following no intervention is 4%, then the risk following intrauterine PRP would be 1% to 24%. When we analyzed all studies (regardless of risk of bias), we found very low-certainty evidence about the effect of intrauterine PRP compared with placebo or no intervention on live birth or ongoing pregnancy (OR 2.38, 95% CI 1.16 to 4.86; I² = 54%; 6 studies, 564 women) and miscarriage (OR 1.54, 95% CI 0.59 to 4.01; I² = 0%; 5 studies, 504 women). The study at low risk of bias provided very low-certainty evidence about the effect of intrauterine PRP compared with no intervention on clinical pregnancy (OR 1.55, 95% CI 0.64 to 3.76; 94 women) and ectopic pregnancy (OR 2.94, 95% CI 0.12 to 73.95; 94 women). The synthesis of all studies provided very low-certainty evidence about the effect of intrauterine PRP compared with placebo or no intervention on clinical pregnancy (OR 2.22, 95% CI 1.50 to 3.27; I² = 24%; 9 studies, 824 women), multiple pregnancy (OR 2.68, 95% CI 0.81 to 8.88; I² = 0%; 2 studies, 240 women), and ectopic pregnancy (OR 2.94, 95% CI 0.12 to 73.95; 1 study, 94 women; very low-certainty evidence). Intrauterine infusion of PRP may increase the risk of preterm delivery compared with no intervention (OR 8.02, 95% CI 1.72 to 37.33; 1 study, 120 women; low-certainty evidence). No studies reported pain, infection, allergic reaction, fetal growth restriction, or fetal abnormality. Intrauterine infusion of platelet-rich plasma versus intrauterine infusion of granulocyte colony-stimulating factor Two RCTs evaluated intrauterine PRP versus intrauterine granulocyte colony-stimulating factor (G-CSF); both included women with thin endometrium, and neither was judged at low risk of bias for any outcome. We are uncertain about the effect of intrauterine PRP compared with intrauterine G-CSF on live birth (OR 0.88, 95% CI 0.43 to 1.81; 1 study, 132 women; very low-certainty evidence), miscarriage (OR 1.94, 95% CI 0.63 to 5.96; 1 study, 132 women; very low-certainty evidence), and clinical pregnancy (OR 1.24, 95% CI 0.66 to 2.35; 2 studies, 172 women; very low-certainty evidence). Neither study reported adverse outcomes other than miscarriage. Intraovarian injection of platelet-rich plasma versus no intervention One RCT evaluated PRP injection into both ovaries versus no intervention; it was judged at high risk of bias for the two outcomes it reported. We are uncertain about the effect of intraovarian PRP injection compared with no intervention on ongoing pregnancy (OR 1.09, 95% CI 0.33 to 3.63; 73 women; very low-certainty evidence) and clinical pregnancy (OR 0.90, 95% CI 0.31 to 2.60; 73 women; very low-certainty evidence). The study examined no safety outcomes. AUTHORS'
conclusionsWe are uncertain about the effect of intrauterine or intraovarian administration of PRP on outcomes of assisted reproduction technology in infertile women. The pooled results should be interpreted with caution. Only one of the 12 included studies was judged at low risk of bias. Other limitations of the included trials were failure to report live birth, poor reporting of methods, lack of prospective protocol registration, low precision due to the small number of enrolled participants, indirectness due to the specific subpopulations and settings studied, and insufficient or absent safety data.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.