Evidence map›Paper›PMID 38682574›Full record

ArticleMedical physics2024

Depth-encoding using optical photon TOF in a prism-PET detector with tapered crystals.

Xinjie Zeng, Andy LaBella, Zipai Wang, Yixin Li, Wanbin Tan, Amir H Goldan

Abstract read
In one paragraph

Article in Medical physics, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Xinjie ZengDepartment of Radiology, Weill Cornell Medical College, Cornell University, New York, New York, USA.
Andy LaBellaDepartment of Radiology, Renaissance School of Medicine, Stony Brook University, Stony Brook, New York, USA.
Zipai WangDepartment of Radiology, Weill Cornell Medical College, Cornell University, New York, New York, USA.
Yixin LiDepartment of Radiology, Weill Cornell Medical College, Cornell University, New York, New York, USA.
Wanbin TanDepartment of Radiology, Weill Cornell Medical College, Cornell University, New York, New York, USA.
Amir H GoldanDepartment of Radiology, Weill Cornell Medical College, Cornell University, New York, New York, USA.

Funding

Prism-PET: A TOF-DOI-Compton PET detector technology for total-body PET imagingR01EB030413 · NIBIB · WEILL MEDICAL COLL OF CORNELL UNIV · PI GOLDAN, AMIRHOSSEIN · 2021 to 2024
$2.5M
NIBIB NIH HHS R01 EB030413NIH HHS R01EB030413
6 · The paper itself

Abstract

backgroundHigh-resolution brain positron emission tomography (PET) scanner is emerging as a significant and transformative non-invasive neuroimaging tool to advance neuroscience research as well as improve diagnosis and treatment in neurology and psychiatry. Time-of-flight (TOF) and depth-of-interaction (DOI) information provide markedly higher PET imaging performance by increasing image signal-to-noise ratio and mitigating spatial resolution degradation due to parallax error, respectively. PET detector modules that utilize light sharing can inherently carry DOI information from the multiple timestamps that are generated per gamma event. The difference between two timestamps that are triggered by scintillation photons traveling in opposite directions signifies the event's depth-dependent optical photon TOF (oTOF). However, light leak at the crystal-readout interface substantially degrades the resolution of this oTOF-based depth encoding. PURPOSE: We demonstrate the feasibility of oTOF-based depth encoding by mitigating light leak in single-ended-readout Prism-PET detector modules using tapered crystals. Minimizing light leak also improved both energy-based DOI and coincidence timing resolutions.

methodsThe tapered Prism-PET module consists of a 16

resultsFor the tapered (non-tapered) Prism-PET module, the measured full width at half maximum (FWHM) energy, timing, energy-based DOI, and oTOF-based DOI resolutions were 8.88 (11.18)%, 243 (286) ps, 2.35 (3.18) mm, and 5.42 (13.87) mm, respectively. The scanner sensitivities using non-tapered and tapered crystals, and 10 rings of detector modules, were simulated to be 30.9 and 29.5 kcps/MBq, respectively.

conclusionsThe tapered Prism-PET module with minimized light leak enabled the first experimental report of oTOF-based depth encoding at the detector module level. It also enabled the utilization of thinner (i.e., 0.1 mm) inter-crystal spacing with barium sulfate as the reflector while also improving energy-based DOI and timing resolutions.

Indexed as

PhotonsPositron-Emission TomographyImage Processing, Computer-AssistedOptical Phenomenadepth‐of‐interactionhigh‐resolutionhigh‐sensitivityprism‐PETtapered crystaltime‐of‐flight

Identifiers

PMID38682574
PMCPMC11518634

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.