Evidence map›Paper›PMID 38682274›Full record

ArticleJournal of synchrotron radiation2024

A closer look at high-energy X-ray-induced bubble formation during soft tissue imaging.

R Patrick Xian, Joseph Brunet, Yuze Huang, Willi L Wagner, Peter D Lee, Paul Tafforeau, Claire L Walsh

Abstract read
In one paragraph

Article in Journal of synchrotron radiation, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers.

0numbers the graph read from it
0cells of the map it votes in
8citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

8 citing papers in PubMed.

  1. Article
  2. Article
  3. The Human Organ Atlas.Science advances · 2026
    Article
  4. Article
  5. Article
  6. Article
  7. Review
  8. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

R Patrick XianDepartment of Mechanical Engineering, University College London, London, United Kingdom.ORCID 0000-0001-9895-6956
Joseph BrunetDepartment of Mechanical Engineering, University College London, London, United Kingdom.ORCID 0000-0002-8424-9510
Yuze HuangDepartment of Mechanical Engineering, University College London, London, United Kingdom.ORCID 0000-0002-9971-6038
Willi L WagnerDepartment of Diagnostic and Interventional Radiology, University Hospital Heidelberg, Heidelberg, Germany.
Peter D LeeDepartment of Mechanical Engineering, University College London, London, United Kingdom.ORCID 0000-0002-3898-8881
Paul TafforeauEuropean Synchrotron Radiation Facility, Grenoble, France.ORCID 0000-0002-5962-1683
Claire L WalshDepartment of Mechanical Engineering, University College London, London, United Kingdom.ORCID 0000-0003-3769-3392

Funding

Medical Research Council MR/R025673/1
6 · The paper itself

Abstract

Improving the scalability of tissue imaging throughput with bright, coherent X-rays requires identifying and mitigating artifacts resulting from the interactions between X-rays and matter. At synchrotron sources, long-term imaging of soft tissues in solution can result in gas bubble formation or cavitation, which dramatically compromises image quality and integrity of the samples. By combining in-line phase-contrast imaging with gas chromatography in real time, we were able to track the onset and evolution of high-energy X-ray-induced gas bubbles in ethanol-embedded soft tissue samples for tens of minutes (two to three times the typical scan times). We demonstrate quantitatively that vacuum degassing of the sample during preparation can significantly delay bubble formation, offering up to a twofold improvement in dose tolerance, depending on the tissue type. However, once nucleated, bubble growth is faster in degassed than undegassed samples, indicating their distinct metastable states at bubble onset. Gas chromatography analysis shows increased solvent vaporization concurrent with bubble formation, yet the quantities of dissolved gasses remain unchanged. By coupling features extracted from the radiographs with computational analysis of bubble characteristics, we uncover dose-controlled kinetics and nucleation site-specific growth. These hallmark signatures provide quantitative constraints on the driving mechanisms of bubble formation and growth. Overall, the observations highlight bubble formation as a critical yet often overlooked hurdle in upscaling X-ray imaging for biological tissues and soft materials and we offer an empirical foundation for their understanding and imaging protocol optimization. More importantly, our approaches establish a top-down scheme to decipher the complex, multiscale radiation-matter interactions in these applications.

Indexed as

SynchrotronsAnimalsChromatography, GasEthanolGasesX-RaysEthanolGasesbubble growthgas chromatographysynchrotron X-raysvacuum degassing

Identifiers

PMID38682274
PMCPMC11075704

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.