Evidence map›Paper›PMID 38681504›Full record

ArticleJournal of applied physics2021

Force spectroscopy with electromagnetic tweezers.

Joseph G Piccolo, Joshua Méndez Harper, Derrica McCalla, Wenxuan Xu, Sam Miller, Jessie Doan, Dan Kovari, David Dunlap, Laura Finzi

Abstract read
In one paragraph

Article in Journal of applied physics, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Article
  2. Article
  3. Force spectroscopy with electromagnetic tweezers.Journal of applied physics · 2021
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors.

Joseph G PiccoloDepartment of Physics, Emory University, 400 Dowman Dr., Atlanta, Georgia 30322, USA.
Joshua Méndez HarperDepartment of Earth Science, University of Oregon, 1272 University of Oregon, Eugene, Oregon 97403, USA.ORCID 0000-0002-0525-4427
Derrica McCallaDepartment of Physics, Emory University, 400 Dowman Dr., Atlanta, Georgia 30322, USA.ORCID 0000-0003-2446-0573
Wenxuan XuDepartment of Physics, Emory University, 400 Dowman Dr., Atlanta, Georgia 30322, USA.ORCID 0000-0002-7305-7951
Sam MillerDepartment of Physics, Emory University, 400 Dowman Dr., Atlanta, Georgia 30322, USA.
Jessie DoanDepartment of Physics, Emory University, 400 Dowman Dr., Atlanta, Georgia 30322, USA.
Dan KovariDepartment of Physics, Emory University, 400 Dowman Dr., Atlanta, Georgia 30322, USA.ORCID 0000-0003-3990-5416
David DunlapDepartment of Physics, Emory University, 400 Dowman Dr., Atlanta, Georgia 30322, USA.ORCID 0000-0003-4352-8318
Laura FinziDepartment of Physics, Emory University, 400 Dowman Dr., Atlanta, Georgia 30322, USA.ORCID 0000-0003-1173-5339

Funding

The lambda bacteriophage regulatory loopR01GM084070 · NIGMS · EMORY UNIVERSITY · PI FINZI, LAURA · 2009 to 2021
$4.1M
NIGMS NIH HHS R01 GM084070
6 · The paper itself

Abstract

Force spectroscopy using magnetic tweezers (MTs) is a powerful method to probe the physical characteristics of single polymers. Typically, molecules are functionalized for specific attachment to a glass surface at one end and a micrometer-scale paramagnetic bead at the other end. By applying an external magnetic field, multiple molecules can be stretched and twisted simultaneously without exposure to potentially damaging radiation. The majority of MTs utilize mobile, permanent magnets to produce forces on the beads (and the molecule under test). However, translating and rotating the permanent magnets may require expensive precision actuators, limit the rate at which force can be changed, and may induce vibrations that disturb tether dynamics and bead tracking. Alternatively, the magnetic field can be produced with an electromagnet, which allows fast force modulation and eliminates motor-associated vibration. Here, we describe a low-cost quadrapolar electromagnetic tweezer design capable of manipulating DNA-tethered MyOne paramagnetic beads with forces as high as 15 pN. The solid-state nature of the generated B-field modulated along two axes is convenient for accessing the range of forces and torques relevant for studying the activity of DNA motor enzymes like polymerases and helicases. Our design specifically leverages technology available at an increasing number of university maker spaces and student-run machine shops. Thus, it is an accessible tool for undergraduate education that is applicable to a wide range of biophysical research questions.

Identifiers

PMID38681504
PMCPMC11055633

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.