SynthesisJournal of clinical monitoring and computing2024
Alternative sensor montage for Index based EEG monitoring. A systematic review.
Synthesis in Journal of clinical monitoring and computing, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
3 citing papers in PubMed.
- Accuracy of Bispectral Index™ monitoring in an alternative nasal position in pediatric patients under general anesthesia: a prospective observational study.Canadian journal of anaesthesia = Journal canadien d'anesthesie · 2026Observational
- Indian expert consensus on intra-operative consciousness monitoring using processed electroencephalogram-based indices: A Delphi-based approach.Indian journal of anaesthesia · 2026Article
- EEG features associated with Alzheimer's disease and Frontotemporal dementia are not reflected by processed indices used in anesthesia monitoring.Journal of clinical monitoring and computing · 2025Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
The main objective of this systematic review is to assess the reliability of alternative positions of processed electroencephalogram sensors for depth of anesthesia monitoring and its applicability in clinical practice. A systematic search was conducted in PubMed, Embase, Cochrane Library, Clinical trial.gov in accordance with reporting guidelines of PRISMA statement together with the following sources: Google and Google Scholar. We considered eligible prospective studies, written in the English language. The last search was run on the August 2023. Risk of bias and quality assessment were performed. Data extraction was performed by two authors and results were synthesized narratively owing to the heterogeneity of the included studies. Thirteen prospective observational studies (438 patients) were included in the systematic review after the final assessment, with significant diversity in study design. Most studies had a low risk of bias but due to lack of information in one key domain of bias (Bias due to missing data) the overall judgement would be No Information. However, there is no clear indication that the studies are at serious or critical risk of bias. Bearing in mind, the heterogeneity and small sample size of the included studies, current evidence suggests that the alternative infraorbital sensor position is the most comparable for clinical use when the standard sensor position in the forehead is not possible.
Indexed as
Identifiers
38676778What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.