Evidence map›Paper›PMID 38676101›Full record

ArticleSensors (Basel, Switzerland)2024

Cardiac Arrhythmia Classification Using Advanced Deep Learning Techniques on Digitized ECG Datasets.

Shoaib Sattar, Rafia Mumtaz, Mamoon Qadir, Sadaf Mumtaz, Muhammad Ajmal Khan, Timo De Waele, Eli De Poorter, Ingrid Moerman, Adnan Shahid

Abstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers.

0numbers the graph read from it
0cells of the map it votes in
7citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

7 citing papers in PubMed.

  1. Article
  2. Article
  3. Review
  4. Article
  5. Article
  6. Article
  7. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors.

Shoaib SattarSchool of Electrical Engineering and Computer Science (SEECS), National University of Sciences and Technology (NUST), Islamabad 44000, Pakistan.
Rafia MumtazSchool of Electrical Engineering and Computer Science (SEECS), National University of Sciences and Technology (NUST), Islamabad 44000, Pakistan.ORCID 0000-0002-0966-3957
Mamoon QadirFederal Government Poly Clinic Hospital, Islamabad 44000, Pakistan.
Sadaf MumtazNUST School of Health Sciences (NSHS), National University of Sciences and Technology (NUST), Islamabad 44000, Pakistan.
Muhammad Ajmal KhanSchool of Electrical Engineering and Computer Science (SEECS), National University of Sciences and Technology (NUST), Islamabad 44000, Pakistan.ORCID 0009-0000-0157-5162
Timo De WaeleIDLab, Department of Information Technology, Ghent University-IMEC, 9052 Ghent, Belgium.
Eli De PoorterIDLab, Department of Information Technology, Ghent University-IMEC, 9052 Ghent, Belgium.ORCID 0000-0002-0214-5751
Ingrid MoermanIDLab, Department of Information Technology, Ghent University-IMEC, 9052 Ghent, Belgium.ORCID 0000-0003-2377-3674
Adnan ShahidIDLab, Department of Information Technology, Ghent University-IMEC, 9052 Ghent, Belgium.ORCID 0000-0003-1943-6261

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

ECG classification or heartbeat classification is an extremely valuable tool in cardiology. Deep learning-based techniques for the analysis of ECG signals assist human experts in the timely diagnosis of cardiac diseases and help save precious lives. This research aims at digitizing a dataset of images of ECG records into time series signals and then applying deep learning (DL) techniques on the digitized dataset. State-of-the-art DL techniques are proposed for the classification of the ECG signals into different cardiac classes. Multiple DL models, including a convolutional neural network (CNN), a long short-term memory (LSTM) network, and a self-supervised learning (SSL)-based model using autoencoders are explored and compared in this study. The models are trained on the dataset generated from ECG plots of patients from various healthcare institutes in Pakistan. First, the ECG images are digitized, segmenting the lead II heartbeats, and then the digitized signals are passed to the proposed deep learning models for classification. Among the different DL models used in this study, the proposed CNN model achieves the highest accuracy of ∼92%. The proposed model is highly accurate and provides fast inference for real-time and direct monitoring of ECG signals that are captured from the electrodes (sensors) placed on different parts of the body. Using the digitized form of ECG signals instead of images for the classification of cardiac arrhythmia allows cardiologists to utilize DL models directly on ECG signals from an ECG machine for the real-time and accurate monitoring of ECGs.

Indexed as

Arrhythmias, CardiacDeep LearningElectrocardiographyNeural Networks, ComputerAlgorithmsHeart RateHumansSignal Processing, Computer-Assistedarrhythmiadeep learningdigitizationECG classificationself-supervised learning

Identifiers

PMID38676101
PMCPMC11054468

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.