Evidence map›Paper›PMID 38676056›Full record

ArticleSensors (Basel, Switzerland)2024

A Method to Track 3D Knee Kinematics by Multi-Channel 3D-Tracked A-Mode Ultrasound.

Kenan Niu, Victor Sluiter, Bangyu Lan, Jasper Homminga, André Sprengers, Nico Verdonschot

Open access · goldAbstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
0.9field-weighted citation impact, top 30% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed, 5 citations in OpenAlex.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 2 institutions in 1 country.

Kenan NiuRobotics and Mechatronics Group, Faculty of Electrical Engineering, Mathematics and Computer Science (EEMCS), University of Twente, P.O. Box 217, 7500 AE Enschede, The Netherlands.ORCID 0000-0002-5498-4311
Victor SluiterDepartment of Biomechanical Engineering, University of Twente, 7521 HK Enschede, The Netherlands.ORCID 0000-0001-8571-7892
Bangyu LanRobotics and Mechatronics Group, Faculty of Electrical Engineering, Mathematics and Computer Science (EEMCS), University of Twente, P.O. Box 217, 7500 AE Enschede, The Netherlands.ORCID 0009-0001-3745-2778
Jasper HommingaDepartment of Biomechanical Engineering, University of Twente, 7521 HK Enschede, The Netherlands.ORCID 0009-0009-4752-2344
André SprengersOrthopaedic Research Lab, Radboud University Medical Center, P.O. Box 9101, 6500 HB Nijmegen, The Netherlands.
Nico VerdonschotDepartment of Biomechanical Engineering, University of Twente, 7521 HK Enschede, The Netherlands.ORCID 0000-0002-7531-6523
University of Twente · NLRadboud University Nijmegen · NL

Funding

European Research Council 323091
6 · The paper itself

Abstract

This paper introduces a method for measuring 3D tibiofemoral kinematics using a multi-channel A-mode ultrasound system under dynamic conditions. The proposed system consists of a multi-channel A-mode ultrasound system integrated with a conventional motion capture system (i.e., optical tracking system). This approach allows for the non-invasive and non-radiative quantification of the tibiofemoral joint's six degrees of freedom (DOF). We demonstrated the feasibility and accuracy of this method in the cadaveric experiment. The knee joint's motions were mimicked by manually manipulating the leg through multiple motion cycles from flexion to extension. To measure it, six custom ultrasound holders, equipped with a total of 30 A-mode ultrasound transducers and 18 optical markers, were mounted on various anatomical regions of the lower extremity of the specimen. During experiments, 3D-tracked intra-cortical bone pins were inserted into the femur and tibia to measure the ground truth of tibiofemoral kinematics. The results were compared with the tibiofemoral kinematics derived from the proposed ultrasound system. The results showed an average rotational error of 1.51 ± 1.13° and a translational error of 3.14 ± 1.72 mm for the ultrasound-derived kinematics, compared to the ground truth. In conclusion, this multi-channel A-mode ultrasound system demonstrated a great potential of effectively measuring tibiofemoral kinematics during dynamic motions. Its improved accuracy, nature of non-invasiveness, and lack of radiation exposure make this method a promising alternative to incorporate into gait analysis and prosthetic kinematic measurements later.

Indexed as

Imaging, Three-DimensionalKnee JointUltrasonographyBiomechanical PhenomenaFemurHumansKneeRange of Motion, ArticularTibiaA-mode ultrasoundgait analysismotion trackingtibiofemoral kinematicswearable ultrasound

Identifiers

PMID38676056
PMCPMC11053743
OpenAlexW4394720820

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.