Evidence map›Paper›PMID 38676052›Full record

ArticleSensors (Basel, Switzerland)2024

Developing and Testing High-Performance SHM Sensors Mounting Low-Noise MEMS Accelerometers.

Marianna Crognale, Cecilia Rinaldi, Francesco Potenza, Vincenzo Gattulli, Andrea Colarieti, Fabio Franchi

Open access · goldAbstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
4.2field-weighted citation impact, top 6% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed, 16 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 3 institutions in 1 country.

Marianna CrognaleDepartment of Structural and Geotechnical Engineering, Sapienza University of Rome, Via Eudossiana 18, 00184 Roma, Italy.ORCID 0000-0002-2190-1866
Cecilia RinaldiDepartment of Structural and Geotechnical Engineering, Sapienza University of Rome, Via Eudossiana 18, 00184 Roma, Italy.ORCID 0000-0003-4178-1467
Francesco PotenzaDepartment of Engineering and Geology, University "G. d'Annunzio" of Chieti-Pescara, Viale Pindaro 42, 65127 Pescara, Italy.ORCID 0000-0002-2862-9930
Vincenzo GattulliDepartment of Structural and Geotechnical Engineering, Sapienza University of Rome, Via Eudossiana 18, 00184 Roma, Italy.ORCID 0000-0002-5336-3687
Andrea ColarietiWest Aquila S.r.l., S.S. 17 snc c/o Tecnopolo d'Abruzzo, 67100 L'Aquila, Italy.
Fabio FranchiDepartment of Information Engineering, Computer Science and Mathematics, Università degli Studi dell'Aquila, Via Vetoio, 67100 L'Aquila, Italy.ORCID 0000-0001-9558-5344
Sapienza University of Rome · ITUniversity of Chieti-Pescara · ITUniversity of L'Aquila · IT

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Recently, there has been increased interest in adopting novel sensing technologies for continuously monitoring structural systems. In this respect, micro-electrical mechanical system (MEMS) sensors are widely used in several applications, including structural health monitoring (SHM), in which accelerometric samples are acquired to perform modal analysis. Thanks to their significantly lower cost, ease of installation in the structure, and lower power consumption, they enable extensive, pervasive, and battery-less monitoring systems. This paper presents an innovative high-performance device for SHM applications, based on a low-noise triaxial MEMS accelerometer, providing a guideline and insightful results about the opportunities and capabilities of these devices. Sensor nodes have been designed, developed, and calibrated to meet structural vibration monitoring and modal identification requirements. These components include a protocol for reliable command dissemination through network and data collection, and improvements to software components for data pipelining, jitter control, and high-frequency sampling. Devices were tested in the lab using shaker excitation. Results demonstrate that MEMS-based accelerometers are a feasible solution to replace expensive piezo-based accelerometers. Deploying MEMS is promising to minimize sensor node energy consumption. Time and frequency domain analyses show that MEMS can correctly detect modal frequencies, which are useful parameters for damage detection. The acquired data from the test bed were used to examine the functioning of the network, data transmission, and data quality. The proposed architecture has been successfully deployed in a real case study to monitor the structural health of the Marcus Aurelius Exedra Hall within the Capitoline Museum of Rome. The performance robustness was demonstrated, and the results showed that the wired sensor network provides dense and accurate vibration data for structural continuous monitoring.

Indexed as

internet of thingsSHM-boardstructural health monitoringultra-low-power micro-controller

Identifiers

PMID38676052
PMCPMC11054890
OpenAlexW4394720899

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.