Evidence map›Paper›PMID 38671159›Full record

ArticleNature materials2024

Electrochemically actuated microelectrodes for minimally invasive peripheral nerve interfaces.

Chaoqun Dong, Alejandro Carnicer-Lombarte, Filippo Bonafè, Botian Huang, Sagnik Middya, Amy Jin, Xudong Tao, Sanggil Han, Manohar Bance, Damiano G Barone and 2 more

Open access · hybridAbstract read
In one paragraph

Article in Nature materials, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 34 papers.

0numbers the graph read from it
0cells of the map it votes in
34citing papers in PubMed
14.0field-weighted citation impact, top 1% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

34 citing papers in PubMed, 76 citations in OpenAlex.

  1. Review
  2. Review
  3. Receptogenesis in a Vascularized Robotic Embodiment.Advanced science (Weinheim, Baden-Wurttemberg, Germany) · 2026
    Article
  4. Review
  5. Article
  6. Article
  7. Wrinkle-Adaptive Kirigami Wearables With Anisotropic Deformability for Sleep EEG Monitoring.Advanced science (Weinheim, Baden-Wurttemberg, Germany) · 2026
    Article
  8. Full-Stack Architectures for Intelligent Brain-Computer Interfaces.Advanced science (Weinheim, Baden-Wurttemberg, Germany) · 2026
    Review
  9. Article
  10. Article
  11. Review
  12. Article
  13. Article
  14. Review
  15. Review
  16. A self-wrapping, bioresorbable neural interface for wireless multimodal therapy of localized peripheral nerve injury.Proceedings of the National Academy of Sciences of the United States of America · 2026
    Article
  17. Article
  18. Article
  19. Review
  20. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

12 authors at 3 institutions in 3 countries.

Chaoqun DongElectrical Engineering Division, Department of Engineering, University of Cambridge, Cambridge, UK.ORCID 0000-0001-6433-3478
Alejandro Carnicer-LombarteElectrical Engineering Division, Department of Engineering, University of Cambridge, Cambridge, UK.ORCID 0000-0002-5650-4692
Filippo BonafèElectrical Engineering Division, Department of Engineering, University of Cambridge, Cambridge, UK.ORCID 0000-0003-2932-9099
Botian HuangElectrical Engineering Division, Department of Engineering, University of Cambridge, Cambridge, UK.
Sagnik MiddyaElectrical Engineering Division, Department of Engineering, University of Cambridge, Cambridge, UK.
Amy JinElectrical Engineering Division, Department of Engineering, University of Cambridge, Cambridge, UK.ORCID 0000-0001-7396-2639
Xudong TaoElectrical Engineering Division, Department of Engineering, University of Cambridge, Cambridge, UK.ORCID 0000-0001-8177-8831
Sanggil HanElectrical Engineering Division, Department of Engineering, University of Cambridge, Cambridge, UK.ORCID 0000-0001-8588-5466
Manohar BanceDepartment of Clinical Neurosciences, University of Cambridge, Cambridge, UK.
Damiano G BaroneElectrical Engineering Division, Department of Engineering, University of Cambridge, Cambridge, UK.ORCID 0000-0002-0091-385X
Beatrice FraboniDepartment of Physics and Astronomy, University of Bologna, Bologna, Italy.ORCID 0000-0002-4875-3816
George G MalliarasElectrical Engineering Division, Department of Engineering, University of Cambridge, Cambridge, UK. gm603@cam.ac.uk.ORCID 0000-0002-4582-8501
University of Cambridge · GBIncheon National University · KRUniversity of Bologna · IT

Funding

RCUK | Engineering and Physical Sciences Research Council (EPSRC) EP/S009000/1
6 · The paper itself

Abstract

Electrode arrays that interface with peripheral nerves are used in the diagnosis and treatment of neurological disorders; however, they require complex placement surgeries that carry a high risk of nerve injury. Here we leverage recent advances in soft robotic actuators and flexible electronics to develop highly conformable nerve cuffs that combine electrochemically driven conducting-polymer-based soft actuators with low-impedance microelectrodes. Driven with applied voltages as small as a few hundreds of millivolts, these cuffs allow active grasping or wrapping around delicate nerves. We validate this technology using in vivo rat models, showing that the cuffs form and maintain a self-closing and reliable bioelectronic interface with the sciatic nerve of rats without the use of surgical sutures or glues. This seamless integration of soft electrochemical actuators with neurotechnology offers a path towards minimally invasive intraoperative monitoring of nerve activity and high-quality bioelectronic interfaces.

Indexed as

MicroelectrodesPeripheral NervesAnimalsElectrochemical TechniquesRatsRats, Sprague-DawleySciatic Nerve

Identifiers

PMID38671159
PMCPMC11230894
OpenAlexW4395686233

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.