Evidence map›Paper›PMID 38669496›Full record

ArticleTechnology and health care : official journal of the European Society for Engineering and Medicine2024

Enhanced acrylic gauge with five eccentric circles for optimizing CT angiography spatial resolution via Taguchi's methodology.

Cheng-Mao Shen, Ya-Hui Lin, Dian-Fong Li, Lung-Kwang Pan, Bing-Ru Peng

Open access · bronzeAbstract read
In one paragraph

Article in Technology and health care : official journal of the European Society for Engineering and Medicine, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
0.2field-weighted citation impact, top 56% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed, 1 citations in OpenAlex.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 4 institutions in 1 country.

Cheng-Mao ShenDepartment of Medical Imaging and Radiological Science, Central Taiwan University of Science and Technology, Taichung, Taiwan.
Ya-Hui LinDepartment of Medical Imaging and Radiological Science, Central Taiwan University of Science and Technology, Taichung, Taiwan.
Dian-Fong LiDepartment of Medical Imaging and Radiological Science, Central Taiwan University of Science and Technology, Taichung, Taiwan.
Lung-Kwang PanDepartment of Medical Imaging and Radiological Science, Central Taiwan University of Science and Technology, Taichung, Taiwan.
Bing-Ru PengDepartment of Medical Imaging and Radiological Science, Central Taiwan University of Science and Technology, Taichung, Taiwan.
Central Taiwan University of Science and Technology · TWTaichung Armed Forces General Hospital · TWTaichung Veterans General Hospital · TWTri-Service General Hospital · TW

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundCerebral examination via CTA is always the first choice for patients with unexpected brain injury or different types of brain lesions to detect ruptured hemangiomas, vascular infarcts, or other brain tissue lesions.

objectiveThis study innovated the acrylic gauge with five eccentric circles for computed tomography angiography (CTA) analysis to optimize the spatial resolution via Taguchi's methodology.

methodsThe customized gauge was revised from the V-shaped slit gauge and transferred into five eccentric circles' slit gauge. The gauge was assembled with another six acrylic layers to simulate the human head. Taguchi's L18 orthogonal array was adopted to optimize the spatial resolution of CTA imaging quality. In doing so, six essential factors of CTA are kVp, mAs, spiral rotation pitch, FOV, rotation time of the CT and reconstruction filter, and each factor has either two or three levels to organize into eighteen combinations to simulate the full factor combination of 486 (21 × 35 = 486) times according to Taguchi's recommendation. Three well-trained radiologists ranked the gauge's 18 CTA scanned imaging qualities according to contrast, sharpness, and spatial resolution and derived the unique fish-bone-plot of six factors for further analysis. The optimal factor combination of CTA was proven by follow-up verification and ANOVA to obtain this study's dominant or minor factor.

resultsThe optimal factor combination of CTA was A2 (120 kVp), B3 (200 mAs), C1 (Pitch 0.6), D2 (FOV 220 mm2), E1 (rotation time 0.33 s), and F3 (Brain sharp, UC). Furthermore, deriving a quantified MDD (minimum detectable difference) to imply the spatial resolution of CTA, a semiauto profile analysis program run in MATLAB and OriginPro was recommended to evaluate the MDD and to suppress the manual error in calculation. Eventually, the derived MDDs of the conventional and optimal factor combinations of CTA were 2.35 and 2.26 mm, respectively, in this study.

conclusionTaguchi's methodology was found applicable for quantifying the CTA imaging quality in practical applications.

Indexed as

Computed Tomography AngiographyHumansPhantoms, ImagingEccentric circles gaugeMDDspatial resolutionTaguchi optimization

Identifiers

PMID38669496
PMCPMC11191523
OpenAlexW4395677085

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.