Evidence map›Paper›PMID 38667558›Full record

ArticleJournal of functional biomaterials2024

Biomechanical Effects of Ti-Base Abutment Height on the Dental Implant System: A Finite Element Analysis.

Miguel Beltrán-Guijarro, Esteban Pérez-Pevida, David Chávarri-Prado, Alejandro Estrada-Martínez, Markel Diéguez-Pereira, Fernando Sánchez-Lasheras, Aritza Brizuela-Velasco

Abstract read
In one paragraph

Article in Journal of functional biomaterials, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers.

0numbers the graph read from it
0cells of the map it votes in
7citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

7 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Miguel Beltrán-GuijarroDepartment of Surgery, Faculty of Medicine, University of Salamanca, 37007 Salamanca, Spain.
Esteban Pérez-PevidaDepartment of Surgery, Faculty of Medicine, University of Salamanca, 37007 Salamanca, Spain.ORCID 0000-0002-3523-5972
David Chávarri-PradoFaculty of Health Sciences, Miguel de Cervantes European University, 47012 Valladolid, Spain.ORCID 0000-0002-3670-3424
Alejandro Estrada-MartínezFaculty of Health Sciences, Miguel de Cervantes European University, 47012 Valladolid, Spain.ORCID 0000-0002-7952-1874
Markel Diéguez-PereiraFaculty of Health Sciences, Miguel de Cervantes European University, 47012 Valladolid, Spain.ORCID 0000-0002-5844-6596
Fernando Sánchez-LasherasDepartment of Mathematics, University Institute of Space Sciences and Technologies of Asturias (ICTEA), University of Oviedo, 33006 Oviedo, Spain.ORCID 0000-0002-7052-2811
Aritza Brizuela-VelascoFaculty of Health Sciences, Miguel de Cervantes European University, 47012 Valladolid, Spain.ORCID 0000-0001-6421-3863

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

This study aims to analyse, using a finite element analysis, the effects of Ti-base abutment height on the distribution and magnitude of transferred load and the resulting bone microstrain in the bone-implant system. A three-dimensional bone model of the mandibular premolar section was created with an implant placed in a juxta-osseous position. Three prosthetic models were designed: a 1 mm-high titanium-base (Ti-base) abutment with an 8 mm-high cemented monolithic zirconia crown was designed for model A, a 2 mm-high Ti-base abutment with a 7 mm-high crown for model B, and a 3 mm-high abutment with a 6 mm-high crown for model C. A static load of 150 N was applied to the central fossa at a six-degree angle with respect to the axial axis of the implant to evaluate the magnitude and distribution of load transfer and microstrain. The results showed a trend towards a direct linear association between the increase in the height of the Ti-base abutments and the increase in the transferred stress and the resulting microstrain to both the prosthetic elements and the bone/implant system. An increase in transferred stress and deformation of all elements of the system, within physiological ranges, was observed as the size of the Ti-base abutment increased.

Indexed as

dental implant biomechanicsfatigue analysisfinite element modelling

Identifiers

PMID38667558
PMCPMC11051524

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.