Evidence map›Paper›PMID 38667154›Full record

ArticleBiosensors2024

Enhancing Glucose Biosensing with Graphene Oxide and Ferrocene-Modified Linear Poly(ethylenimine).

Jirawan Monkrathok, Pattanaphong Janphuang, Somphong Suphachiaraphan, Sastiya Kampaengsri, Anyanee Kamkaew, Kantapat Chansaenpak, Sireerat Lisnund, Vincent Blay, Piyanut Pinyou

Abstract read
In one paragraph

Article in Biosensors, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers.

0numbers the graph read from it
0cells of the map it votes in
8citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

8 citing papers in PubMed.

  1. Review
  2. Review
  3. Review
  4. Article
  5. Review
  6. Review
  7. Review
  8. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors.

Jirawan MonkrathokSchool of Chemistry, Institute of Science, Suranaree University of Technology, 111 University Ave., Nakhon Ratchasima 30000, Thailand.
Pattanaphong JanphuangSynchrotron Light Research Institute (Public Organization), 111 University Ave., Nakhon Ratchasima 30000, Thailand.
Somphong SuphachiaraphanSynchrotron Light Research Institute (Public Organization), 111 University Ave., Nakhon Ratchasima 30000, Thailand.
Sastiya KampaengsriSchool of Chemistry, Institute of Science, Suranaree University of Technology, 111 University Ave., Nakhon Ratchasima 30000, Thailand.
Anyanee KamkaewSchool of Chemistry, Institute of Science, Suranaree University of Technology, 111 University Ave., Nakhon Ratchasima 30000, Thailand.ORCID 0000-0003-1203-2686
Kantapat ChansaenpakNational Nanotechnology Center, National Science and Technology Development Agency, Thailand Science Park, Pathum Thani 12120, Thailand.
Sireerat LisnundDepartment of Applied Chemistry, Faculty of Science and Liberal Arts, Rajamangala University of Technology Isan, 744 Suranarai Rd., Nakhon Ratchasima 30000, Thailand.
Vincent BlayDepartment of Microbiology and Environmental Toxicology, University of California at Santa Cruz, Santa Cruz, CA 95064, USA.ORCID 0000-0001-9602-2375
Piyanut PinyouSchool of Chemistry, Institute of Science, Suranaree University of Technology, 111 University Ave., Nakhon Ratchasima 30000, Thailand.ORCID 0000-0001-7978-1898

Funding

The Program Management Unit for Human Resources & Institutional Development, Research and Innovation (PMU-B) B13F660067
6 · The paper itself

Abstract

We designed and optimized a glucose biosensor system based on a screen-printed electrode modified with the NAD-GDH enzyme. To enhance the electroactive surface area and improve the electron transfer efficiency, we introduced graphene oxide (GO) and ferrocene-modified linear poly(ethylenimine) (LPEI-Fc) onto the biosensor surface. This strategic modification exploits the electrostatic interaction between graphene oxide, which possesses a negative charge, and LPEI-Fc, which is positively charged. This interaction results in increased catalytic current during glucose oxidation and helps improve the overall glucose detection sensitivity by amperometry. We integrated the developed glucose sensor into a flow injection (FI) system. This integration facilitates a swift and reproducible detection of glucose, and it also mitigates the risk of contamination during the analyses. The incorporation of an FI system improves the efficiency of the biosensor, ensuring precise and reliable results in a short time. The proposed sensor was operated at a constant applied potential of 0.35 V. After optimizing the system, a linear calibration curve was obtained for the concentration range of 1.0-40 mM (R

Indexed as

Biosensing TechniquesFerrous CompoundsGlucoseGraphiteMetallocenesPolyethyleneimineElectrodesOxidation-ReductionferroceneFerrous CompoundsGlucosegraphene oxideGraphiteMetallocenesPolyethyleneimineflow injectionglucose biosensorglucose dehydrogenasegraphene oxideredox polymer

Identifiers

PMID38667154
PMCPMC11048651

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.