ArticleAdvanced materials technologies2024

Contact pressure-guided wearable dual-channel bioimpedance device for continuous hemodynamic monitoring.

Myeong Namkoong, Justin McMurray, Kimberly Branan, Joanna Hernandez, Mishika Gandhi, Samuel Ida-Oze, Gerard Cote, Limei Tian

Abstract read
In one paragraph

Article in Advanced materials technologies, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers.

0numbers the graph read from it
0cells of the map it votes in
7citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

7 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Intrinsic PPG-ECG Coupling for Accurate and Low-Power Blood Pressure Monitoring.Advanced science (Weinheim, Baden-Wurttemberg, Germany) · 2026
    Article
  5. Article
  6. Article
  7. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Myeong NamkoongDepartment of Biomedical Engineering, and Center for Remote Health Technologies and Systems, Texas A&M University, College Station, TX 77843, USA.
Justin McMurrayDepartment of Biomedical Engineering, and Center for Remote Health Technologies and Systems, Texas A&M University, College Station, TX 77843, USA.
Kimberly BrananDepartment of Biomedical Engineering, and Center for Remote Health Technologies and Systems, Texas A&M University, College Station, TX 77843, USA.
Joanna HernandezDepartment of Biomedical Engineering, and Center for Remote Health Technologies and Systems, Texas A&M University, College Station, TX 77843, USA.
Mishika GandhiDepartment of Biomedical Engineering, and Center for Remote Health Technologies and Systems, Texas A&M University, College Station, TX 77843, USA.
Samuel Ida-OzeDepartment of Biomedical Engineering, and Center for Remote Health Technologies and Systems, Texas A&M University, College Station, TX 77843, USA.
Gerard CoteDepartment of Biomedical Engineering, and Center for Remote Health Technologies and Systems, Texas A&M University, College Station, TX 77843, USA.
Limei TianDepartment of Biomedical Engineering, and Center for Remote Health Technologies and Systems, Texas A&M University, College Station, TX 77843, USA.

Funding

Refreshable Biosensors for Continuous Renal Function MonitoringR21EB029064 · NIBIB · TEXAS ENGINEERING EXPERIMENT STATION · PI TIAN, LIMEI · 2020 to 2020
$589k
NIBIB NIH HHS R21 EB029064
6 · The paper itself

Abstract

Wearable devices for continuous monitoring of arterial pulse waves have the potential to improve the diagnosis, prognosis, and management of cardiovascular diseases. These pulse wave signals are often affected by the contact pressure between the wearable device and the skin, limiting the accuracy and reliability of hemodynamic parameter quantification. Here, we report a continuous hemodynamic monitoring device that enables the simultaneous recording of dual-channel bioimpedance and quantification of pulse wave velocity (PWV) used to calculate blood pressure (BP). Our investigations demonstrate the effect of contact pressure on bioimpedance and PWV. The pulsatile bioimpedance magnitude reached its maximum when the contact pressure approximated the mean arterial pressure of the subject. We employed PWV to continuously quantify BP while maintaining comfortable contact pressure for prolonged wear. The mean absolute error and standard deviation of the error compared to the reference value were determined to be 0.1 ± 3.3 mmHg for systolic BP, 1.3 ± 3.7 mmHg for diastolic BP, and -0.4 ± 3.0 mmHg for mean arterial pressure when measurements were conducted in the lying down position. This research demonstrates the potential of wearable dual-bioimpedance sensors with contact pressure guidance for reliable and continuous hemodynamic monitoring.

Indexed as

contact pressurecuffless blood pressurehemodynamic monitoringpulse wave velocitywearable bioimpedance sensors

Identifiers

PMID38665229
PMCPMC11044990

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.