ArticleAdvanced materials technologies2024
Contact pressure-guided wearable dual-channel bioimpedance device for continuous hemodynamic monitoring.
Article in Advanced materials technologies, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
7 citing papers in PubMed.
- Laser-Induced Graphene Electrodes for Wrist-Worn Impedance Plethysmography Measurements: A Feasibility Study.Biosensors · 2026Article
- Ultrasound-enabled refreshable electrochemical sensors for cardiac biomarker monitoring.Biosensors & bioelectronics · 2026Article
- Soft, Skin-Conformal Electronic Interfaces for Multimodal Biosignal Monitoring and Transcutaneous Stimulation.ACS applied materials & interfaces · 2026Article
- Intrinsic PPG-ECG Coupling for Accurate and Low-Power Blood Pressure Monitoring.Advanced science (Weinheim, Baden-Wurttemberg, Germany) · 2026Article
- Flexible thermal array sensor for imperceptible monitoring of multidimensional vascular dynamics.Science advances · 2026Article
- Segmental bioimpedance and anthropometry improve machine learning prediction of grip strength in healthy young adults.Frontiers in bioengineering and biotechnology · 2026Article
- Exploration of the Conditions for Occurrence of Photoplethysmographic Signal Inversion above the Dorsalis Pedis Artery.Sensors (Basel, Switzerland) · 2024Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
8 authors.
Funding
Abstract
Wearable devices for continuous monitoring of arterial pulse waves have the potential to improve the diagnosis, prognosis, and management of cardiovascular diseases. These pulse wave signals are often affected by the contact pressure between the wearable device and the skin, limiting the accuracy and reliability of hemodynamic parameter quantification. Here, we report a continuous hemodynamic monitoring device that enables the simultaneous recording of dual-channel bioimpedance and quantification of pulse wave velocity (PWV) used to calculate blood pressure (BP). Our investigations demonstrate the effect of contact pressure on bioimpedance and PWV. The pulsatile bioimpedance magnitude reached its maximum when the contact pressure approximated the mean arterial pressure of the subject. We employed PWV to continuously quantify BP while maintaining comfortable contact pressure for prolonged wear. The mean absolute error and standard deviation of the error compared to the reference value were determined to be 0.1 ± 3.3 mmHg for systolic BP, 1.3 ± 3.7 mmHg for diastolic BP, and -0.4 ± 3.0 mmHg for mean arterial pressure when measurements were conducted in the lying down position. This research demonstrates the potential of wearable dual-bioimpedance sensors with contact pressure guidance for reliable and continuous hemodynamic monitoring.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.