Evidence map›Paper›PMID 38664983›Full record

ArticleJournal of applied clinical medical physics2024

Comparison of failure modes and effects analyses and time for brachytherapy ring and tandem applicator digitization between manual and solid applicator source placement methods.

Adia L Holtman, Dominic J DiCostanzo, Charles A Zimmerman, Gavin Graeper, Jeffrey Woollard, Daniel F Christ, Ashley J Cetnar

Open access · goldAbstract readComparative Study
In one paragraph

Article in Journal of applied clinical medical physics, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
1.2field-weighted citation impact, top 24% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed, 2 citations in OpenAlex.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 1 institution in 1 country.

Adia L HoltmanDepartment of Radiation Oncology, The Ohio State University, Columbus, Ohio, USA.
Dominic J DiCostanzoDepartment of Radiation Oncology, The Ohio State University, Columbus, Ohio, USA.ORCID https://orcid.org/0000-0002-3222-7141
Charles A ZimmermanDepartment of Radiation Oncology, The Ohio State University, Columbus, Ohio, USA.
Gavin GraeperDepartment of Radiation Oncology, The Ohio State University, Columbus, Ohio, USA.ORCID https://orcid.org/0000-0003-1026-6489
Jeffrey WoollardDepartment of Radiation Oncology, The Ohio State University, Columbus, Ohio, USA.
Daniel F ChristDepartment of Radiation Oncology, The Ohio State University, Columbus, Ohio, USA.
Ashley J CetnarDepartment of Radiation Oncology, The Ohio State University, Columbus, Ohio, USA.ORCID https://orcid.org/0000-0003-4004-0763
The Ohio State University · US

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeRing and tandem (R&T) applicator digitization is currently performed at our institution by manually defining the extent of the applicators. Digitization can also be achieved using solid applicators: predefined, 3D models with geometric constraints. This study compares R&T digitization using manual and solid applicator methods through Failure Modes and Effects Analyses (FMEAs) and comparative time studies. We aim to assess the suitability of solid applicator method implementation for R&T cases

methodsSix qualified medical physicists (QMPs) and two medical physics residents scored potential modes of failure of manual digitization in an FMEA as recommended by TG-100. Occurrence, severity, and detectability (OSD) values were averaged across respondents and then multiplied to form combined Risk Priority Numbers (RPNs) for analysis. Participants were trained to perform treatment planning using a developed solid applicator protocol and asked to score a second FMEA on the distinct process steps from the manual method. For both methods, participant digitization was timed. FMEA and time data were analyzed across methods and participant samples

resultsQMPs rated the RPNs of the current, manual method of digitization statistically lower than residents did. When comparing the unique FMEA steps between the two digitization methods, QMP respondents found no significant difference in RPN means. Residents, however, rated the solid applicator method as higher risk. Further, after the solid applicator method was performed twice by participants, the time to digitize plans was not significantly different from manual digitization

conclusionsThis study indicates the non-inferiority of the solid applicator method to manual digitization in terms of risk, according to QMPs, and time, across all participants. Differences were found in FMEA evaluation and solid applicator technique adoption based on years of brachytherapy experience. Further practice with the solid applicator protocol is recommended because familiarity is expected to lower FMEA occurrence ratings and further reduce digitization times.

Indexed as

BrachytherapyRadiotherapy DosageRadiotherapy Planning, Computer-AssistedHealthcare Failure Mode and Effect AnalysisHumansNeoplasmsapplicator digitizationbrachytherapyring and tandemsolid applicator

Identifiers

PMID38664983
PMCPMC11087182
OpenAlexW4395672939

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.