Evidence map›Paper›PMID 38661997›Full record

ArticleArchives of orthopaedic and trauma surgery2024

Accuracy of portable navigation during THA in patients with severe developmental dysplasia of hip.

Shinya Hayashi, Yuichi Kuroda, Naoki Nakano, Tomoyuki Matsumoto, Tomoyuki Kamenaga, Masanori Tsubosaka, Ryosuke Kuroda

Abstract read
PubMed Publisher
In one paragraph

Article in Archives of orthopaedic and trauma surgery, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
1.7field-weighted citation impact, top 17% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed, 3 citations in OpenAlex.

  1. Article
  2. [Advances in application of digital orthopedic technology in total hip arthroplasty for developmental dysplasia of hip].Zhongguo xiu fu chong jian wai ke za zhi = Zhongguo xiufu chongjian waike zazhi = Chinese journal of reparative and reconstructive surgery · 2026
    Review
  3. Article
  4. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 1 institution in 1 country.

Shinya HayashiDepartment of Orthopaedic Surgery, Kobe University Graduate School of Medicine, 7-5-1 Kusunoki-cho, Chuo-ku, Kobe, 650-0017, Japan. shayashi@med.kobe-u.ac.jp.ORCID http://orcid.org/0000-0003-4308-9845
Yuichi KurodaDepartment of Orthopaedic Surgery, Kobe University Graduate School of Medicine, 7-5-1 Kusunoki-cho, Chuo-ku, Kobe, 650-0017, Japan.
Naoki NakanoDepartment of Orthopaedic Surgery, Kobe University Graduate School of Medicine, 7-5-1 Kusunoki-cho, Chuo-ku, Kobe, 650-0017, Japan.
Tomoyuki MatsumotoDepartment of Orthopaedic Surgery, Kobe University Graduate School of Medicine, 7-5-1 Kusunoki-cho, Chuo-ku, Kobe, 650-0017, Japan.
Tomoyuki KamenagaDepartment of Orthopaedic Surgery, Kobe University Graduate School of Medicine, 7-5-1 Kusunoki-cho, Chuo-ku, Kobe, 650-0017, Japan.
Masanori TsubosakaDepartment of Orthopaedic Surgery, Kobe University Graduate School of Medicine, 7-5-1 Kusunoki-cho, Chuo-ku, Kobe, 650-0017, Japan.
Ryosuke KurodaDepartment of Orthopaedic Surgery, Kobe University Graduate School of Medicine, 7-5-1 Kusunoki-cho, Chuo-ku, Kobe, 650-0017, Japan.
Kobe University · JP

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

introductionCorrect cup placement in total hip arthroplasty (THA) for patients with developmental dysplasia of the hip (DDH) is considerably difficult. This study aimed to analyze the orientation accuracy of cup insertion during THA using a portable navigation system in patients with DDH. MATERIALS AND

methodsIn this retrospective cohort study, we analyzed data from 64 patients who underwent THA using infrared stereo camera-matching portable navigation. Patients underwent THA via the anterolateral approach in the lateral decubitus position. Navigation records for intraoperative cup angles, postoperative cup angles measured on computed tomography (CT) images, and cup angle measurement differences were measured and compared between patients with non-DDH/mild DDH and severe DDH. Furthermore, the predictive factors for outliers of accurate acetabular cup placement were analyzed.

resultsThe average measurement absolute abduction differences (postoperative CT-navigation record) were 3.9 ± 3.5° (severe DDH) and 3.3 ± 2.6° (non-DDH/ mild DDH), and the anteversion differences were 4.7 ± 3.4° (severe DDH) and 2.3 ± 2.1° (non-DDH/ mild DDH). The anteversion difference was different between the two groups. Multivariate analysis showed that the navigation difference (absolute difference in anteversion between postoperative CT and navigation records of > 5°) was significantly associated with severe DDH (odds ratio [OR]: 3.3; p = 0.049, 95% confidence interval [CI]: 1.0-11.1) and posterior pelvic tilt (OR: 1.1; p = 0.042, 95% CI: 1.0-1.27).

conclusionsIn patients with severe DDH, it is important to pay close attention during THA using portable navigation. However, the average difference was < 5º even in patients with severe DDH, and the accuracy may be acceptable in a clinical setting when the cost is considered.

Indexed as

Arthroplasty, Replacement, HipDevelopmental Dysplasia of the HipAdultAgedFemaleHip ProsthesisHumansMaleMiddle AgedRetrospective StudiesSurgery, Computer-AssistedSurgical Navigation SystemsTomography, X-Ray ComputedDevelopmental dysplasia of the hipPortable navigationPosterior pelvic tiltTotal hip arthroplasty

Identifiers

PMID38661997
OpenAlexW4395464119

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.