Electron streaming dose measurements and calculations on a 1.5 T MR-Linac.

Elizabeth Patterson, Marcus Powers, Peter E Metcalfe, Dean Cutajar, Bradley M Oborn, John A Baines

Open access · goldAbstract read
In one paragraph

Article in Journal of applied clinical medical physics, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed
4.3field-weighted citation impact, top 6% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

6 citing papers in PubMed, 7 citations in OpenAlex.

  1. Article
  2. Review
  3. Review
  4. Article
  5. Article
  6. Electron streaming dose measurements and calculations on a 1.5 T MR-Linac.Journal of applied clinical medical physics · 2024
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 2 institutions in 2 countries.

Elizabeth PattersonCentre for Medical and Radiation Physics, University of Wollongong, Wollongong, New South Wales, Australia.ORCID https://orcid.org/0000-0002-6240-2887
Marcus PowersCollege of Science and Engineering, James Cook University, Townsville, Queensland, Australia.ORCID https://orcid.org/0000-0002-4235-6123
Peter E MetcalfeCentre for Medical and Radiation Physics, University of Wollongong, Wollongong, New South Wales, Australia.ORCID https://orcid.org/0000-0002-6820-0055
Dean CutajarCentre for Medical and Radiation Physics, University of Wollongong, Wollongong, New South Wales, Australia.ORCID https://orcid.org/0000-0002-4384-7856
Bradley M ObornCentre for Medical and Radiation Physics, University of Wollongong, Wollongong, New South Wales, Australia.ORCID https://orcid.org/0000-0002-1672-6231
John A BainesCollege of Science and Engineering, James Cook University, Townsville, Queensland, Australia.ORCID https://orcid.org/0000-0002-5013-1100
University of Wollongong · AUTownsville Hospital · AU

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeTo evaluate the accuracy of different dosimeters and the treatment planning system (TPS) for assessing the skin dose due to the electron streaming effect (ESE) on a 1.5 T magnetic resonance (MR)-linac.

methodSkin dose due to the ESE on an MR-linac (Unity, Elekta) was investigated using a solid water phantom rotated 45° in the x-y plane (IEC61217) and centered at the isocenter. The phantom was irradiated with 1 × 1, 3 × 3, 5 × 5, 10 × 10, and 22 × 22 cm

resultsOSLD, film, the 0.1 cm, 0.2%, and 0.2 cm, 3.0% TPS ESE doses, underestimated skin doses measured by the MOSkin™ by as much as -75.3%, -7.0%, -24.7%, and -41.9%, respectively. Film results were most similar to MOSkin™ skin dose measurements.

conclusionsThese results show that electron streams can deposit significant doses outside the primary field and that dosimeter choice and TPS calculation settings greatly influence the reported readings. Due to the steep dose gradient of the ESE, EBT3 film remains the choice for accurate skin dose assessment in this challenging environment.

Indexed as

ElectronsMagnetic Resonance ImagingParticle AcceleratorsPhantoms, ImagingRadiotherapy DosageRadiotherapy Planning, Computer-AssistedHumansMonte Carlo MethodRadiotherapy, Intensity-ModulatedSkinelectron streaming effectElekta UnityMonaco UnityMRgRTMR‐linacout‐of‐field doseskin dose

Identifiers

PMID38661097
PMCPMC11244671
OpenAlexW4395464199

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.