ArticleBMC pulmonary medicine2024
Embosphere microspheres size for bronchial artery embolization in patients with hemoptysis caused by bronchiectasis: a retrospective comparative analysis of 500-750 versus 700-900 μm microspheres.
Article in BMC pulmonary medicine, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
6 citing papers in PubMed, 5 citations in OpenAlex.
- Bronchial Artery Embolisation in Haemoptysis Management: A Scoping Review with Emphasis on Embolic Materials and Indications.Advances in respiratory medicine · 2025Article
- The effect of Angio-CT on the efficacy of hemoptysis patients with non-bronchial systemic arteries-a retrospective study.Cardiovascular diagnosis and therapy · 2025Article
- Risk factors of hemoptysis recurrence after bronchial artery embolization and patient feedbacks.Turk gogus kalp damar cerrahisi dergisi · 2025Article
- Application of an advanced steerable microcatheter for challenging arterial embolization in massive hemoptysis.Journal of thoracic disease · 2025Article
- Development and validation of a nomogram for predicting hemoptysis recurrence in cystic bronchiectasis patients following bronchial artery embolization.Frontiers in medicine · 2025Article
- Bronchiectasis morphology and hemoptysis recurrence after bronchial artery embolization: a cohort study using inverse probability of treatment weighting.Frontiers in medicine · 2025Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
3 authors at 1 institution in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundBronchial arterial embolization (BAE) has been accepted as an effective treatment for bronchiectasis-related hemoptysis. However, rare clinical trials compare different sizes of specific embolic agents. This study aims to evaluate whether different Embosphere microsphere sizes change the outcome of BAE.
methodsA retrospective review was conducted on consecutive patients with bronchiectatic hemoptysis who were scheduled to undergo BAE treatment during a period from January 2018 to December 2022. The patients received BAE using microspheres of different sizes: group A patients were treated with 500-750 μm microspheres, and group B patients were treated with 700-900 μm microspheres. The cost of embolic microspheres (Chinese Yuan, CNY), duration of hospitalization, complications, and hemoptysis-free survival were compared between patients in group A and those in group B. A Cox proportional hazards regression model was used to identify predictors of recurrent hemoptysis.
resultsMedian follow-up was 30.2 months (range, 20.3-56.5 months). The final analysis included a total of 112 patients (49-77 years of age; 45 men). The patients were divided into two groups: group A (N = 68), which received 500-750 μm Embosphere microspheres, and group B (N = 44), which received 700-900 μm Embosphere microspheres. Except for the cost of embolic microspheres(group A,5314.8 + 1301.5 CNY; group B, 3644.5 + 1192.3 CNY; p = 0.042), there were no statistically significant differences in duration of hospitalization (group A,7.2 + 1.4 days; group B, 8 + 2.4days; p = 0.550), hemoptysis-free survival (group A, 1-year, 2-year, 3-year, 85.9%, 75.8%, 62.9%; group B, 1-year, 2-year, 3-year, 88.4%, 81.2%,59.4%;P = 0.060), and complications(group A,26.5%; group B, 38.6%; p = 0.175) between the two groups. No major complications were observed. The multivariate analysis results revealed that the presence of cystic bronchiectasis (OR 1.61, 95% CI 1.12-2.83; P = 0.001) and systemic arterial-pulmonary shunts (SPSs) (OR 1.52, 95% CI 1.10-2.72; P = 0.028) were independent risk factors for recurrent bleeding.
conclusionsFor the treatment of BAE in patients with bronchiectasis-related hemoptysis, 500-750 μm diameter Embosphere microspheres have a similar efficacy and safety profile compared to 700-900 μm diameter Embosphere microspheres, especially for those without SPSs or cystic bronchiectasis. Furthermore, the utilization of large-sized (700-900 μm) Embosphere microspheres is associated with the reduced cost of an embolic agent.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.