Safety and efficacy of fluoroscopy-guided urethral catheterization in case of failed blind or cystoscopy-assisted urethral catheterization.

Sang Woo Kim, In Chul Nam, Doo Ri Kim, Jeong Sub Lee, Jeong Jae Kim, Bong Su Kim, Guk Myung Choi, Sung Eun Park

Open access · goldAbstract read
In one paragraph

Article in Scientific reports, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
0.5field-weighted citation impact, top 36% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed, 1 citations in OpenAlex.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors at 3 institutions in 1 country.

Sang Woo KimDepartment of Radiology, Jeju National University School of Medicine, Jeju National University Hospital, 15, Aran 13-gil, Jeju, 63241, Republic of Korea.
In Chul NamDepartment of Radiology, Jeju National University School of Medicine, Jeju National University Hospital, 15, Aran 13-gil, Jeju, 63241, Republic of Korea. sky_hall@naver.com.
Doo Ri KimDepartment of Radiology, Jeju National University School of Medicine, Jeju National University Hospital, 15, Aran 13-gil, Jeju, 63241, Republic of Korea.
Jeong Sub LeeDepartment of Radiology, Jeju National University School of Medicine, Jeju National University Hospital, 15, Aran 13-gil, Jeju, 63241, Republic of Korea.
Jeong Jae KimDepartment of Radiology, Jeju National University School of Medicine, Jeju National University Hospital, 15, Aran 13-gil, Jeju, 63241, Republic of Korea.
Bong Su KimDepartment of Radiology, Jeju National University School of Medicine, Jeju National University Hospital, 15, Aran 13-gil, Jeju, 63241, Republic of Korea.
Guk Myung ChoiDepartment of Radiology, Jeju National University School of Medicine, Jeju National University Hospital, 15, Aran 13-gil, Jeju, 63241, Republic of Korea.
Sung Eun ParkDepartment of Radiology, Gyeongsang National University School of Medicine, Gyeongsang National University Changwon Hospital, 11 Samjeongja-ro, Seongsan-gu, Changwon, 51472, Republic of Korea.
Jeju National University Hospital · KRJeju National University · KRChangwon National University · KR

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

This retrospective study evaluated the safety and efficacy of fluoroscopy-guided urethral catheterization in patients who failed blind or cystoscopy-assisted urethral catheterization. We utilized our institutional database between January 2011 and March 2023, and patients with failed blind or cystoscopy-assisted urethral catheterization and subsequent fluoroscopy-guided urethral catheterization were included. A 5-Fr catheter was inserted into the urethral orifice, and the retrograde urethrography (RGU) was acquired. Subsequently, the operator attempted to pass a hydrophilic guidewire to the urethra. If the guidewire and guiding catheter could be successfully passed into the bladder, but the urethral catheter failed pass due to urethral stricture, the operator determined either attempted again with a reduced catheter diameter or performed balloon dilation according to their preference. Finally, an appropriately sized urethral catheter was selected, and an endhole was created using an 18-gauge needle. The catheter was then inserted over the wire to position the tip in the bladder lumen and ballooned to secure it. We reviewed patients' medical histories, the presence of hematuria, and RGU to determine urethral abnormalities. Procedure-related data were assessed. Study enrolled a total of 179 fluoroscopy-guided urethral catheterizations from 149 patients (all males; mean age, 73.3 ± 13.3 years). A total of 225 urethral strictures were confirmed in 141 patients, while eight patients had no strictures. Urethral rupture was confirmed in 62 patients, and hematuria occurred in 34 patients after blind or cystoscopy-assisted urethral catheterization failed. Technical and clinical success rates were 100%, and procedure-related complications were observed in four patients (2.2%). The mean time from request to urethral catheter insertion was 129.7 ± 127.8 min. The mean total fluoroscopy time was 3.5 ± 2.5 min and the mean total DAP was 25.4 ± 25.1 Gy cm

Indexed as

CystoscopyUrethral StrictureUrinary CatheterizationAgedAged, 80 and overFluoroscopyHumansMaleMiddle AgedRetrospective StudiesUrethra

Identifiers

PMID38658695
PMCPMC11043067
OpenAlexW4395081582

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.