Evidence map›Paper›PMID 38658477›Full record

ArticleAnnals of biomedical engineering2024

Evaluation of Apparatus and Protocols to Measure Human Passive Neck Stiffness and Range of Motion.

Mingyue Liu, Ryan D Quarrington, Baptiste Sandoz, William S P Robertson, Claire F Jones

Open access · hybridAbstract read
In one paragraph

Article in Annals of biomedical engineering, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
1.3field-weighted citation impact, top 20% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed, 3 citations in OpenAlex.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 3 institutions in 2 countries.

Mingyue LiuSchool of Electrical and Mechanical Engineering, The University of Adelaide, Adelaide, SA, Australia.ORCID http://orcid.org/0000-0001-8455-5115
Ryan D QuarringtonSchool of Electrical and Mechanical Engineering, The University of Adelaide, Adelaide, SA, Australia.ORCID http://orcid.org/0000-0002-0633-2482
Baptiste SandozArts et Métiers Institute of Technology, Université Sorbonne Paris Nord, IBHGC - Institut de Biomécanique Humaine Georges Charpak, HESAM Université, Paris, France.ORCID http://orcid.org/0000-0002-9054-2617
William S P RobertsonSchool of Electrical and Mechanical Engineering, The University of Adelaide, Adelaide, SA, Australia.ORCID http://orcid.org/0000-0001-7351-8378
Claire F JonesSchool of Electrical and Mechanical Engineering, The University of Adelaide, Adelaide, SA, Australia. claire.jones@adelaide.edu.au.ORCID http://orcid.org/0000-0002-0995-1182
The University of Adelaide · AUArts et Métiers · FRRoyal Adelaide Hospital · AU

Funding

Hospital Research Foundation C-PJ-151-Exper-2019
6 · The paper itself

Abstract

Understanding of human neck stiffness and range of motion (ROM) with minimal neck muscle activation ("passive") is important for clinical and bioengineering applications. The aim of this study was to develop, implement, and evaluate the reliability of methods for assessing passive-lying stiffness and ROM, in six head-neck rotation directions. Six participants completed two assessment sessions. To perform passive-lying tests, the participant's head and torso were strapped to a bending (flexion, extension, lateral bending) or a rotation (axial rotation) apparatus, and clinical bed, respectively. The head and neck were manually rotated by the researcher to the participant's maximum ROM, to assess passive-lying stiffness. Participant-initiated ("active") head ROM was also assessed in the apparatus, and seated. Various measures of apparatus functionality were assessed. ROM was similar for all assessment configurations in each motion direction except flexion. In each direction, passive stiffness generally increased throughout neck rotation. Within-session reliability for stiffness (ICC > 0.656) and ROM (ICC > 0.872) was acceptable, but between-session reliability was low for some motion directions, probably due to intrinsic participant factors, participant-apparatus interaction, and the relatively low participant number. Moment-angle corridors from both assessment sessions were similar, suggesting that with greater sample size, these methods may be suitable for estimating population-level corridors.

Indexed as

NeckRange of Motion, ArticularAdultFemaleHumansMaleNeck MusclesRotationActive motionCervical spineElectromyographyIn vivoMethodMotion capturePassive motionRepeatability

Identifiers

PMID38658477
PMCPMC11247060
OpenAlexW4395069188

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.