Disinfection of needleless connectors for catheters in one second using a hand-held UV device.

Michael Fourkas, Eri Takami, Gregory J Schears, Shauna Farr-Jones, Julia Rasooly

Open access · hybridAbstract read
In one paragraph

Article in American journal of infection control, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
0.7field-weighted citation impact, top 32% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed, 1 citations in OpenAlex.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 3 institutions in 1 country.

Michael FourkasPuraCath Medical Inc., Newark, CA.
Eri TakamiPuraCath Medical Inc., Newark, CA.
Gregory J SchearsDepartment of Anesthesiology and Perioperative Medicine, Mayo Clinic, Rochester, MN.
Shauna Farr-JonesDepartment of Anesthesia and Perioperative Care, University of California, Zuckerberg San Francisco Hospital, San Francisco, CA.
Julia RasoolyPuraCath Medical Inc., Newark, CA. Electronic address: jrasooly@puracath.com.
PuraCath Medical (United States) · USMayo Clinic in Arizona · USSan Francisco General Hospital · US

Funding

Therapeutic UV Disinfection System to Prevent Catheter Related Bloodstream Infections (CRBSIs) in Patients with Peripherally Inserted Central Catheters (PICCs)R44AI134553 · NIAID · PURACATH MEDICAL, INC. · PI FOURKAS, MICHAEL, RASOOLY, JULIA · 2020 to 2022
$3.0M
Therapeutic UV Disinfection System to Prevent Catheter Related Bloodstream Infections (CRBSIs) in Patients with Peripherally Inserted Central Catheters (PICCs)SB1AI174371 · NIAID · PURACATH MEDICAL, INC. · PI FOURKAS, MICHAEL, RASOOLY, JULIA · 2023 to 2025
$3.0M
A device to reduce catheter related bloodstream infection rates in patients with peripherally inserted central catheters (PICCs)R43AI134553 · NIAID · PURACATH MEDICAL, INC. · PI ASHLEY, JOHN E, RASOOLY, JULIA · 2017 to 2017
$223k
NIAID NIH HHS R43 AI134553NIAID NIH HHS R44 AI134553NIAID NIH HHS SB1 AI174371
6 · The paper itself

Abstract

backgroundThe standard of care for disinfecting needleless connectors (NCs) of central venous catheters includes alcohol-containing caps or up to a 15-second scrub with alcohol or chlorhexidine. Due to the clinical impact and high cost of treating Central line-associated bloodstream infections (CLABSI), reducing the incidence of CLABSI is a priority for public health and of the Centers for Disease Control. Alcohol-containing caps have been demonstrated to disinfect external NC surfaces, but not the internal surface. Ultraviolet light (UV-C) is a strategy for disinfection of NC internal and external surfaces.

methodsFour clinically relevant bacteria (Staphylococcus aureus, Staphylococcus epidermidis, Escherichia coli, Pseudomonas aeruginosa) and Candida albicans were inoculated on NCs. Disinfection efficacy was measured after exposure to one second of 285 nm UV-C light at 48 mW/cm

resultsA 4-log reduction in colony forming units (CFUs) on the interior and exterior surfaces of the UV-transparent NC of clinically relevant pathogens was observed with UV-C light at this power for 1 second. DISCUSSION: We demonstrated the efficacy of UV-C for the disinfection of NCs in one second using the UV-C device in benchtop studies.

conclusionsThis device holds promise for reducing CLABSI, and clinical studies are planned.

Indexed as

DisinfectionUltraviolet RaysBacteriaCandida albicansCatheter-Related InfectionsCentral Venous CathetersColony Count, MicrobialHumansCatheter disinfectionCatheter line associated bloodstream infectionCLABSI preventionUltravioletUV-disinfection

Identifiers

PMID38657905
PMCPMC11260529
OpenAlexW4394997151

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.