Evidence map›Paper›PMID 38655304›Full record

ArticleHeliyon2024

Improved accuracy in IoT-Based water quality monitoring for aquaculture tanks using low-cost sensors: Asian seabass fish farming.

Nurshahida Azreen Mohd Jais, Ahmad Fikri Abdullah, Muhamad Saufi Mohd Kassim, Murni Marlina Abd Karim, Abdulsalam M, Nur 'Atirah Muhadi

Abstract read
In one paragraph

Article in Heliyon, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
8citing papers in PubMed, 1 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

8 citing papers in PubMed, 1 synthesis or guideline pooled it.

  1. Pooled it
  2. Article
  3. Review
  4. Article
  5. Article
  6. Article
  7. Article
  8. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Nurshahida Azreen Mohd JaisInternational Institute of Aquaculture and Aquatic Sciences (I-AQUAS), Universiti Putra Malaysia, Lot 960 Jln Kemang 6, 71050, Port Dickson, Negeri Sembilan, Malaysia.
Ahmad Fikri AbdullahInternational Institute of Aquaculture and Aquatic Sciences (I-AQUAS), Universiti Putra Malaysia, Lot 960 Jln Kemang 6, 71050, Port Dickson, Negeri Sembilan, Malaysia.
Muhamad Saufi Mohd KassimDepartment of Biological and Agricultural Engineering, Faculty of Engineering, Universiti Putra Malaysia, 43400, UPM Serdang, Selangor, Malaysia.
Murni Marlina Abd KarimInternational Institute of Aquaculture and Aquatic Sciences (I-AQUAS), Universiti Putra Malaysia, Lot 960 Jln Kemang 6, 71050, Port Dickson, Negeri Sembilan, Malaysia.
Abdulsalam MInternational Institute of Aquaculture and Aquatic Sciences (I-AQUAS), Universiti Putra Malaysia, Lot 960 Jln Kemang 6, 71050, Port Dickson, Negeri Sembilan, Malaysia.
Nur 'Atirah MuhadiDepartment of Biological and Agricultural Engineering, Faculty of Engineering, Universiti Putra Malaysia, 43400, UPM Serdang, Selangor, Malaysia.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Traditional approaches to monitoring water quality in aquaculture tanks present numerous limitations, including the inability to provide real-time data, which can lead to improper feeding practices, reduced productivity, and potential environmental risks. To address these challenges, this study aimed to create an accurate water quality monitoring system for Asian seabass fish farming in aquaculture tanks. This was achieved by enhancing the accuracy of low-cost sensors using simple linear regression and validating the IoT system data with YSI Professional Pro. The system's development and validation were conducted over three months, employing professional devices for accuracy assessment. The accuracy of low-cost sensors was significantly improved through simple linear regression. The results demonstrated impressive accuracy levels ranging from 76% to 97%. The relative error values which range from 0.27% to 4% demonstrate a smaller range compared to the values obtained from the YSI probe during the validation process, signifying the enhanced accuracy and reliability of the IoT sensor by using simple linear regression. The system's enhanced accuracy facilitates convenient and reliable real-time water quality monitoring for aquafarmers. Real-time data visualization was achieved through a microcontroller, Thingspeak, Virtuino application, and ESP 8266 Wi-Fi module, providing comprehensive insights into water quality conditions. Overall, this adaptable tool holds promise for accurate water quality management in diverse aquatic farming practices, ultimately leading to improved yields and sustainability.

Indexed as

Aquaculture tankIoTLow-cost sensorSelf-designed casing sensorSimple linear regressionWater quality monitoring

Identifiers

PMID38655304
PMCPMC11035052

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.