Evidence map›Paper›PMID 38652399›Full record

ArticleThe international journal of cardiovascular imaging2024

Artificial intelligence-enhanced automation for M-mode echocardiographic analysis: ensuring fully automated, reliable, and reproducible measurements.

Dawun Jeong, Sunghee Jung, Yeonyee E Yoon, Jaeik Jeon, Yeonggul Jang, Seongmin Ha, Youngtaek Hong, JunHeum Cho, Seung-Ah Lee, Hong-Mi Choi and 1 more

Abstract readMulticenter StudyEvaluation Study
PubMed Publisher
In one paragraph

Article in The international journal of cardiovascular imaging, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed.

  1. EchoVisuALL: From Echocardiography to Gene Discovery.bioRxiv : the preprint server for biology · 2026
    Article
  2. Article
  3. Article
  4. Article
  5. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

11 authors.

Dawun Jeong *Department of Internal Medicine, Graduate School of Medical Science, Brain Korea 21 Project, Yonsei University College of Medicine, Seoul, South Korea.
Sunghee Jung *CONNECT-AI Research Center, Yonsei University College of Medicine, Seoul, South Korea.
Yeonyee E YoonOntact Health Inc, Seoul, South Korea. yeonyeeyoon@gmail.com.
Jaeik JeonOntact Health Inc, Seoul, South Korea.
Yeonggul JangOntact Health Inc, Seoul, South Korea.
Seongmin HaCONNECT-AI Research Center, Yonsei University College of Medicine, Seoul, South Korea.
Youngtaek HongCONNECT-AI Research Center, Yonsei University College of Medicine, Seoul, South Korea.
JunHeum ChoOntact Health Inc, Seoul, South Korea.
Seung-Ah LeeOntact Health Inc, Seoul, South Korea.
Hong-Mi ChoiCardiovascular Center and Division of Cardiology, Department of Internal Medicine, Seoul National University Bundang Hospital, Gumi-Ro 173, Bundang-Gu, Seongnam, Gyeonggi-Do, 13620, South Korea.
Hyuk-Jae ChangCONNECT-AI Research Center, Yonsei University College of Medicine, Seoul, South Korea.

Funding

Institute of Information & communications Technology Planning & Evaluation (IITP), Korea No. 2022000972
6 · The paper itself

Abstract

To enhance M-mode echocardiography's utility for measuring cardiac structures, we developed and evaluated an artificial intelligence (AI)-based automated analysis system for M-mode images through the aorta and left atrium [M-mode (Ao-LA)], and through the left ventricle [M-mode (LV)]. Our system, integrating two deep neural networks (DNN) for view classification and image segmentation, alongside an auto-measurement algorithm, was developed using 5,958 M-mode images [3,258 M-mode (LA-Ao), and 2,700 M-mode (LV)] drawn from a nationwide echocardiographic dataset collated from five tertiary hospitals. The performance of view classification and segmentation DNNs were evaluated on 594 M-mode images, while automatic measurement accuracy was tested on separate internal test set with 100 M-mode images as well as external test set with 280 images (140 sinus rhythm and 140 atrial fibrillation). Performance evaluation showed the view classification DNN's overall accuracy of 99.8% and segmentation DNN's Dice similarity coefficient of 94.3%. Within the internal test set, all automated measurements, including LA, Ao, and LV wall and cavity, resonated strongly with expert evaluations, exhibiting Pearson's correlation coefficients (PCCs) of 0.81-0.99. This performance persisted in the external test set for both sinus rhythm (PCC, 0.84-0.98) and atrial fibrillation (PCC, 0.70-0.97). Notably, automatic measurements, consistently offering multi-cardiac cycle readings, showcased a stronger correlation with the averaged multi-cycle manual measurements than with those of a single representative cycle. Our AI-based system for automatic M-mode echocardiographic analysis demonstrated excellent accuracy, reproducibility, and speed. This automated approach has the potential to improve efficiency and reduce variability in clinical practice.

Indexed as

AutomationEchocardiographyImage Interpretation, Computer-AssistedPredictive Value of TestsAgedAortaArtificial IntelligenceAtrial FibrillationDatabases, FactualDatasets as TopicDeep LearningFemaleHeart AtriaHeart VentriclesHumansMaleArtificial IntelligenceAutomatic quantificationDeep learningEchocardiographyM-mode

Identifiers

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.