Evidence map›Paper›PMID 38652163›Full record

ArticleClinical neuroradiology2024

Comparison of Flow Reduction Efficacy of Nominal and Oversized Flow Diverters Using a Novel Measurement-assisted in Silico Method.

Benjamin Csippa, Levente Sándor, Gábor Závodszky, István Szikora, György Paál

Abstract readComparative Study
In one paragraph

Article in Clinical neuroradiology, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Benjamin CsippaDepartment of Hydrodynamic Systems, Faculty of Mechanical Engineering,, Budapest University of Technology and Economics, Műegyetem rkp 1-3, 1111, Budapest, Hungary. bcsippa@hds.bme.hu.ORCID http://orcid.org/0000-0002-6072-9712
Levente SándorDepartment of Hydrodynamic Systems, Faculty of Mechanical Engineering,, Budapest University of Technology and Economics, Műegyetem rkp 1-3, 1111, Budapest, Hungary.
Gábor ZávodszkyDepartment of Hydrodynamic Systems, Faculty of Mechanical Engineering,, Budapest University of Technology and Economics, Műegyetem rkp 1-3, 1111, Budapest, Hungary.
István SzikoraNational Institute of Mental Health, Neurology, and Neurosurgery, Department of Neurointerventions, Budapest, Hungary.
György PaálDepartment of Hydrodynamic Systems, Faculty of Mechanical Engineering,, Budapest University of Technology and Economics, Műegyetem rkp 1-3, 1111, Budapest, Hungary.

Funding

H2020 Societal Challenges 101016503Nemzeti Kutatási, Fejlesztési és Innovaciós Alap TKP2021-EGA-02
6 · The paper itself

Abstract

purposeThe high efficacy of flow diverters (FD) in the case of wide-neck aneurysms is well demonstrated, yet new challenges have arisen because of reported posttreatment failures and the growing number of new generation of devices. Our aim is to present a measurement-supported in silico workflow that automates the virtual deployment and subsequent hemodynamic analysis of FDs. In this work, the objective is to analyze the effects of FD deployment variability of two manufacturers on posttreatment flow reduction.

methodsThe virtual deployment procedure is based on detailed mechanical calibration of the flow diverters, while the flow representation is based on hydrodynamic resistance (HR) measurements. Computational fluid dynamic simulations resulted in 5 untreated and 80 virtually treated scenarios, including 2 FD designs in nominal and oversized deployment states. The simulated aneurysmal velocity reduction (AMVR) is correlated with the HR values and deployment scenarios.

resultsThe linear HR coefficient and AMVR revealed a power-law relationship considering all 80 deployments. In nominal deployment scenarios, a significantly larger average AMVR was obtained (60.3%) for the 64-wire FDs than for 48-wire FDs (51.9%). In oversized deployments, the average AMVR was almost the same for 64-wire and 48-wire device types, 27.5% and 25.7%, respectively.

conclusionThe applicability of our numerical workflow was demonstrated, also in large-scale hemodynamic investigations. The study revealed a robust power-law relationship between a HR coefficient and AMVR. Furthermore, the 64 wire configurations in nominal sizing produced a significantly higher posttreatment flow reduction, replicating the results of other in vitro studies.

Indexed as

Computer SimulationIntracranial AneurysmBlood Flow VelocityEndovascular ProceduresHemodynamicsHumansHydrodynamicsModels, CardiovascularProsthesis DesignStentsAneurysmCFDHemodynamicsInterventionStroke

Identifiers

PMID38652163
PMCPMC11339181

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.