ArticleJournal of pediatric orthopedics2024
Screw Diameter and Use of a Washer Affect Symptomatic Implant Removal Rates in Pediatric Medial Epicondyle Fractures.
Article in Journal of pediatric orthopedics, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
5 citing papers in PubMed, 6 citations in OpenAlex.
- Outcomes and complications of metallic vs. bioabsorbable screw fixation for displaced medial epicondylar fractures in pediatric and adolescent patients.European journal of trauma and emergency surgery : official publication of the European Trauma Society · 2026Article
- Clinical outcomes of management of primary medial epicondylar fractures: A systematic review with meta-analysis.Journal of children's orthopaedics · 2026Review
- Implant Removal Complications in Pediatric Orthopedics.Revista brasileira de ortopedia · 2025Article
- [Implant Removal Complications in Pediatric Orthopedics].Revista brasileira de ortopedia · 2025Article
- Clinical and surgical factors influencing screw breakage during hardware removal following periacetabular osteotomy.Journal of hip preservation surgery · 2024Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
8 authors at 2 institutions in 1 country.
Funding
Abstract
objectiveMedial epicondyle fractures are a common pediatric injury. When operative, cannulated partially threaded screws, with or without a washer, are commonly utilized. These implants may need to be removed after full healing if symptomatic. There is mixed evidence regarding the influence of a washer on rates of implant removal, and the influence of screw size has not been studied. We aim to determine the rate of symptomatic deep implant removal for each fixation type and identify factors associated with the need for removal.
methodsThis was an IRB-reviewed, retrospective, case-cohort study. Patients treated at our institution between January 1, 2004 and December 31, 2019, age 18 years old or younger, with a medial epicondyle fracture managed operatively with 4.0 or 4.5 mm cannulated screws with or without washers were included. Patients with multiple operative ipsilateral elbow fractures and those who underwent implant removal for reasons other than pain or irritation were excluded. Removal rates were compared between screw sizes (4.0 vs 4.5 mm), as well as with and without a washer using a Cox proportional hazards model.
resultsIn total, 151 patients met the inclusion criteria, 54 with symptomatic hardware removed and 97 without symptomatic hardware removed. A significantly higher number of patients treated with 4.5 mm screws compared with 4.0 mm screws underwent removal of symptomatic deep implants (50% vs 30%, P = 0.033). In a multivariable Cox regression model adjusting for age and ulnar nerve status, when no washer was used, the hazard ratio (HR) for symptomatic hardware removal for 4.5 mm screws was 2.92 times the HR for 4.0 mm screws (95% CI: 1.35-6.29). When a 4.0 mm screw was used, the HR for symptomatic hardware removal for a washer was 3.24 times the HR without a washer (95% CI: 1.53-6.84).
conclusionImplant removal rates are influenced by screw size and the use of a washer. These results may help guide implant choice and counsel families regarding the rate of symptomatic implant removal. LEVEL OF EVIDENCE: Level III-therapeutic level, case-control study.