Evidence map›Paper›PMID 38649889›Full record

ArticleBreast cancer research : BCR2024

Screening mammography performance according to breast density: a comparison between radiologists versus standalone intelligence detection.

Mi-Ri Kwon, Yoosoo Chang, Soo-Youn Ham, Yoosun Cho, Eun Young Kim, Jeonggyu Kang, Eun Kyung Park, Ki Hwan Kim, Minjeong Kim, Tae Soo Kim and 7 more

Abstract readComparative Study
In one paragraph

Article in Breast cancer research : BCR, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 15 papers, 2 of them syntheses that pooled it.

0numbers the graph read from it
0cells of the map it votes in
15citing papers in PubMed, 2 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

15 citing papers in PubMed, 2 syntheses or guidelines pooled it.

  1. Pooled it
  2. Pooled it
  3. Review
  4. Article
  5. Observational
  6. Article
  7. Review
  8. Article
  9. Review
  10. Article
  11. Article
  12. Article
  13. Article
  14. Review
  15. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

17 authors.

Mi-Ri Kwon *Department of Radiology, Kangbuk Samsung Hospital, Sungkyunkwan University School of Medicine, Seoul, South Korea.ORCID 0000-0001-8225-3690
Yoosoo Chang *Center for Cohort Studies, Kangbuk Samsung Hospital, Sungkyunkwan University School of Medicine, Samsung Main Building B2, 250, Taepyung-ro 2ga, Jung-gu, 04514, Seoul, South Korea. yoosoo.chang@gmail.com.ORCID 0000-0002-6945-9050
Soo-Youn Ham *Department of Radiology, Kangbuk Samsung Hospital, Sungkyunkwan University School of Medicine, Seoul, South Korea.ORCID 0000-0002-5333-9839
Yoosun ChoCenter for Cohort Studies, Kangbuk Samsung Hospital, Sungkyunkwan University School of Medicine, Samsung Main Building B2, 250, Taepyung-ro 2ga, Jung-gu, 04514, Seoul, South Korea.ORCID 0000-0001-5366-3455
Eun Young KimDepartment of Surgery, Kangbuk Samsung Hospital, Sungkyunkwan University School of Medicine, Seoul, Republic of Korea.ORCID 0000-0002-5816-6519
Jeonggyu KangCenter for Cohort Studies, Kangbuk Samsung Hospital, Sungkyunkwan University School of Medicine, Samsung Main Building B2, 250, Taepyung-ro 2ga, Jung-gu, 04514, Seoul, South Korea.ORCID 0000-0002-3516-2822
Eun Kyung ParkLunit Inc, Seoul, Republic of Korea.ORCID 0000-0002-5388-9515
Ki Hwan KimLunit Inc, Seoul, Republic of Korea.ORCID 0000-0001-7684-235X
Minjeong KimLunit Inc, Seoul, Republic of Korea.ORCID 0009-0008-5090-6077
Tae Soo KimLunit Inc, Seoul, Republic of Korea.ORCID 0009-0007-0726-9597
Hyeonsoo LeeLunit Inc, Seoul, Republic of Korea.ORCID 0009-0004-3697-8470
Ria KwonCenter for Cohort Studies, Kangbuk Samsung Hospital, Sungkyunkwan University School of Medicine, Samsung Main Building B2, 250, Taepyung-ro 2ga, Jung-gu, 04514, Seoul, South Korea.ORCID 0000-0001-5314-6861
Ga-Young LimCenter for Cohort Studies, Kangbuk Samsung Hospital, Sungkyunkwan University School of Medicine, Samsung Main Building B2, 250, Taepyung-ro 2ga, Jung-gu, 04514, Seoul, South Korea.ORCID 0000-0003-3155-2740
Hye Rin ChoiCenter for Cohort Studies, Kangbuk Samsung Hospital, Sungkyunkwan University School of Medicine, Samsung Main Building B2, 250, Taepyung-ro 2ga, Jung-gu, 04514, Seoul, South Korea.ORCID 0000-0002-4373-2581
JunHyeok ChoiSchool of Mechanical Engineering, Sunkyungkwan University, Seoul, Republic of Korea.ORCID 0009-0002-4042-4011
Shin Ho KookDepartment of Radiology, Kangbuk Samsung Hospital, Sungkyunkwan University School of Medicine, Seoul, South Korea.ORCID 0000-0001-9843-1148
Seungho Ryu *Center for Cohort Studies, Kangbuk Samsung Hospital, Sungkyunkwan University School of Medicine, Samsung Main Building B2, 250, Taepyung-ro 2ga, Jung-gu, 04514, Seoul, South Korea. sh703.yoo@gmail.com.ORCID 0000-0002-3927-8646

Funding

Sungkyunkwan University SKKU Excellence in Research Award Research Fund
6 · The paper itself

Abstract

backgroundArtificial intelligence (AI) algorithms for the independent assessment of screening mammograms have not been well established in a large screening cohort of Asian women. We compared the performance of screening digital mammography considering breast density, between radiologists and AI standalone detection among Korean women.

methodsWe retrospectively included 89,855 Korean women who underwent their initial screening digital mammography from 2009 to 2020. Breast cancer within 12 months of the screening mammography was the reference standard, according to the National Cancer Registry. Lunit software was used to determine the probability of malignancy scores, with a cutoff of 10% for breast cancer detection. The AI's performance was compared with that of the final Breast Imaging Reporting and Data System category, as recorded by breast radiologists. Breast density was classified into four categories (A-D) based on the radiologist and AI-based assessments. The performance metrics (cancer detection rate [CDR], sensitivity, specificity, positive predictive value [PPV], recall rate, and area under the receiver operating characteristic curve [AUC]) were compared across breast density categories.

resultsMean participant age was 43.5 ± 8.7 years; 143 breast cancer cases were identified within 12 months. The CDRs (1.1/1000 examination) and sensitivity values showed no significant differences between radiologist and AI-based results (69.9% [95% confidence interval [CI], 61.7-77.3] vs. 67.1% [95% CI, 58.8-74.8]). However, the AI algorithm showed better specificity (93.0% [95% CI, 92.9-93.2] vs. 77.6% [95% CI, 61.7-77.9]), PPV (1.5% [95% CI, 1.2-1.9] vs. 0.5% [95% CI, 0.4-0.6]), recall rate (7.1% [95% CI, 6.9-7.2] vs. 22.5% [95% CI, 22.2-22.7]), and AUC values (0.8 [95% CI, 0.76-0.84] vs. 0.74 [95% CI, 0.7-0.78]) (all P < 0.05). Radiologist and AI-based results showed the best performance in the non-dense category; the CDR and sensitivity were higher for radiologists in the heterogeneously dense category (P = 0.059). However, the specificity, PPV, and recall rate consistently favored AI-based results across all categories, including the extremely dense category.

conclusionsAI-based software showed slightly lower sensitivity, although the difference was not statistically significant. However, it outperformed radiologists in recall rate, specificity, PPV, and AUC, with disparities most prominent in extremely dense breast tissue.

Indexed as

Artificial IntelligenceBreast DensityBreast NeoplasmsEarly Detection of CancerMammographyRadiologistsAdultAlgorithmsBreastFemaleHumansMass ScreeningMiddle AgedRepublic of KoreaRetrospective StudiesROC CurveAsian womenBreastIntelligenceMammographyScreening

Identifiers

PMID38649889
PMCPMC11036604

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.