Evidence map›Paper›PMID 38649861›Full record

ArticleBMC ophthalmology2024

Extended depth of focus IOL in eyes with different axial myopia and targeted refraction.

Xiaohui Wang, Sinan Liu, Yinqi Chen, Jinping Gong, Nuozhou Wu, Yihua Yao

Open access · goldAbstract read
In one paragraph

Article in BMC ophthalmology, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers.

0numbers the graph read from it
0cells of the map it votes in
7citing papers in PubMed
3.9field-weighted citation impact, top 6% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

7 citing papers in PubMed, 10 citations in OpenAlex.

  1. Review
  2. Review
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 1 institution in 1 country.

Xiaohui Wang *Department of Ophthalmology, The First Affiliated Hospital of Fujian Medical University, 20 Cha Zhong Road, 350005, Fujian, Fujian, China. xhwangfjmu@126.com.
Sinan Liu *Department of Ophthalmology, The First Affiliated Hospital of Fujian Medical University, 20 Cha Zhong Road, 350005, Fujian, Fujian, China.
Yinqi Chen *Department of Ophthalmology, The First Affiliated Hospital of Fujian Medical University, 20 Cha Zhong Road, 350005, Fujian, Fujian, China.
Jinping Gong *Department of Ophthalmology, The First Affiliated Hospital of Fujian Medical University, 20 Cha Zhong Road, 350005, Fujian, Fujian, China.
Nuozhou WuDepartment of Ophthalmology, The First Affiliated Hospital of Fujian Medical University, 20 Cha Zhong Road, 350005, Fujian, Fujian, China.
Yihua YaoDepartment of Ophthalmology, The First Affiliated Hospital of Fujian Medical University, 20 Cha Zhong Road, 350005, Fujian, Fujian, China.
First Affiliated Hospital of Fujian Medical University · CN

Funding

Joint Funds for the Innovation of Science and Technology, Fujian Province 2021Y9013Medical Innovation Project of Fujian Provincial Health Commission 2021CXA021Natural Science Foundation of Fujian Province 2023J01591
6 · The paper itself

Abstract

aimTo evaluate the objective visual outcomes following implantation of extended depth of focus intraocular lens (EDOF IOL) in individuals with varying axial lengths (AL) and targeted refraction.

methodsThis retrospective study comprised age-matched eyes that underwent implantation of the EDOF IOL. Eyes were categorized based on AL into groups: control group with AL < 26 mm; high myopia group with AL ≥ 26 mm. Each group was then subdivided based on postoperative spherical equivalent (SE). Follow-up at three months included assessment of uncorrected visual acuity at different distances, contrast sensitivity (CS), refractive outcomes, and spectacle independence.

resultsOverall, this study included 100 eyes from 100 patients, comprising 50 males (50.00%) and 50 females (50.00%), with 20 eyes in each group. In the control group, the uncorrected distance visual acuity (UDVA) at 5 and 3 m (m) in the - 1.50 to -0.75 group was inferior to that of the - 0.75 to 0.00 group (P = 0.004). Conversely, the uncorrected near visual acuity (UNVA) at 33 cm in the - 1.50 to -0.75 group was superior to that of the - 0.75 to 0.00 group (P = 0.005). Within the high myopia group, the UDVA at 5 and 3 m in the - 2.25 to -1.50 group was worse than in the - 0.75 to 0.00 group (P = 0.009 and 0.008, respectively). However, the UNVA at 33 cm in the - 2.25 to -1.50 group was better than in the - 0.75 to 0.00 group (P = 0.020). No significant differences were observed among the groups for corrected distance visual acuity (CDVA) (P > 0.05). Additionally, in the high myopia group, the CS of the - 2.25 to -1.50 group was lower compared to that of the - 0.75 to 0.00 group (P = 0.017). Among high myopia patients, 90.00% with refraction ranging from - 1.50 to -0.75 reported achieving overall spectacle independence.

conclusionsImplantation of extended depth of focus intraocular lenses (IOLs) yields satisfactory visual and refractive outcomes in eyes with axial myopia. Among high myopia patients, a refraction ranging from - 1.50 to -0.75 diopters achieves superior visual quality compared to other postoperative myopic diopters.

Indexed as

Lenses, IntraocularLens Implantation, IntraocularMyopiaRefraction, OcularVisual AcuityAdultAgedAxial Length, EyeContrast SensitivityDepth PerceptionFemaleFollow-Up StudiesHumansMaleMiddle AgedPhacoemulsificationAxial lengthCataract surgeryExtended depth of focusHigh myopiaIntraocular lensMyopic targetVisual results

Identifiers

PMID38649861
PMCPMC11036644
OpenAlexW4395012208

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.