Evidence map›Paper›PMID 38645814›Full record

ArticleCentral European journal of urology2024

Retrograde intrarenal surgery using the ILY robotic flexible ureteroscope: a single centre experience.

Jan Łaszkiewicz, Wojciech Krajewski, Łukasz Nowak, Joanna Chorbińska, Francesco Del Giudice, Aleksandra Sójka, Małgorzata Mazur, Szymon Pisarski, Wojciech Tomczak, Bartosz Małkiewicz and 1 more

Open access · greenAbstract read
In one paragraph

Article in Central European journal of urology, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
1.3field-weighted citation impact, top 21% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed, 3 citations in OpenAlex.

  1. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

11 authors at 2 institutions in 2 countries.

Jan ŁaszkiewiczUniversity Center of Excellence in Urology, Wrocław Medical University, Wrocław, Poland.
Wojciech KrajewskiDepartment of Minimally Invasive and Robotic Urology, University Center of Excellence in Urology Wrocław Medical University, Wrocław, Poland.
Łukasz NowakDepartment of Minimally Invasive and Robotic Urology, University Center of Excellence in Urology Wrocław Medical University, Wrocław, Poland.
Joanna ChorbińskaDepartment of Minimally Invasive and Robotic Urology, University Center of Excellence in Urology Wrocław Medical University, Wrocław, Poland.
Francesco Del GiudiceDepartment of Urology, Policlinico Umberto I, Sapienza University of Rome, Rome, Italy.
Aleksandra SójkaUniversity Center of Excellence in Urology, Wrocław Medical University, Wrocław, Poland.
Małgorzata MazurUniversity Center of Excellence in Urology, Wrocław Medical University, Wrocław, Poland.
Szymon PisarskiUniversity Center of Excellence in Urology, Wrocław Medical University, Wrocław, Poland.
Wojciech TomczakUniversity Center of Excellence in Urology, Wrocław Medical University, Wrocław, Poland.
Bartosz MałkiewiczDepartment of Minimally Invasive and Robotic Urology, University Center of Excellence in Urology Wrocław Medical University, Wrocław, Poland.
Tomasz SzydełkoUniversity Center of Excellence in Urology, Wrocław Medical University, Wrocław, Poland.
Wroclaw Medical University · PLPoliclinico Umberto I · IT

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Introduction: The ILY robotic flexible ureteroscope has been introduced in order to improve intraoperative ergonomics, reduce operator distance from radiation and shorten the learning curve. In this study we aimed to assess the clinical performance and feasibility of the ILY robot during retrograde intrarenal surgery (RIRS) and combined endoscopic procedures (miniECIRS). Material and methods: The RIRS procedures were performed using the ILY robotic arm in 57 adult patients (46 RIRS and 11 miniECIRS) from 2022 to 2023. All procedures were performed in the supine position. Pre-stenting was not the standard of care. Results: Turning on and calibration of the device took approximately 100 s. Average draping time was 93 s using original ILY drapes and 47 s using classic drapes designed for C-arm covering. Mean docking time was 73 s in procedures with ureteral access sheath (UAS) and 61 s in procedures without it. The undocking took less than 60 s in every case. Average procedure time was 63 min for RIRS and 55 min for miniECIRS. Endoscopically proven stone-free rate was achieved in 37 (80.4%) RIRS and 10 (90.9%) miniECIRS patients. A total of 17 (36.9%) RIRS and 8 (72.7%) miniECIRS procedures required conversion in order to perform basketing and stone fragments retrieval/transposition. Conclusions: The use of ILY robot during endourological procedures is feasible and urologists that are familiar with the device controller do not require extensive training. The time needed for device draping, docking and undocking was approximately 4 minutes. Moreover, use of the robot resulted in satisfactory stone-free rates.

Indexed as

ECIRSkidney calculiRIRSrobotic endourologyurolithiasis

Identifiers

PMID38645814
PMCPMC11032040
OpenAlexW4392394833

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-SA
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.