ArticleTurkish journal of ophthalmology2024
Comparison of Spot Vision Screener and Tabletop Autorefractometer with Retinoscopy in the Pediatric Population.
Article in Turkish journal of ophthalmology, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
5 citing papers in PubMed.
- Comparison of refractive parameters provided by a new open field aberrometer and the subjective refraction.BMC ophthalmology · 2026Observational
- Clinical Evaluation of an Affordable Handheld Wavefront Autorefractor in an Adult Population in a Low-Resource Setting in the Amazonas.Vision (Basel, Switzerland) · 2025Article
- Evaluation of Portable, Low-Cost Autorefractor in School Students with Limited Eye Care Access in Northeastern Brazil.Vision (Basel, Switzerland) · 2025Article
- Reliability of handheld autorefractometers in patients after cataract surgery.Turkish journal of medical sciences · 2025Article
- Instrument-based, non-cycloplegic versus cycloplegic refraction in pediatric and young adult populations (≤25 years): A systematic review and meta-analysis.Advances in ophthalmology practice and researchReview
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
3 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Objectives: Determining the accuracy of cycloplegic refractive error measurements made with the Spot Vision Screener (SVS, Welch Allyn Inc, Skaneateles Falls, NY, USA) is important for refractive assessment of uncooperative patients during optometric examinations. This study compared cycloplegic refractive errors measured by SVS and tabletop autorefractometer to cycloplegic retinoscopy in children. Materials and Methods: Eighty-eight eyes of 44 subjects were examined in the study. Refractive error measurements were obtained under cycloplegia using retinoscopy, SVS, and Nidek ARK-530 tabletop autorefractometer (ARK-530, Nidek, Japan). Spherical and cylindrical values, spherical equivalents (SE), and Jackson cross-cylinder values at axes of 0° (J0) and 45° (J45) were recorded. Correlations between methods were analyzed using intraclass correlation coefficient (ICC) and Bland-Altman analysis. Results: The mean age was 7 years (range: 6 months-17 years). Sixteen (36%) of the subjects were female and 28 (64%) were male. For SE there was excellent agreement between retinoscopy and SVS (ICC: 0.924) and between retinoscopy and tabletop autorefractometer (ICC: 0.995). While there was a moderate correlation between retinoscopy and SVS for cylindrical values (ICC: 0.686), excellent correlation was detected between retinoscopy and autorefractometer (ICC: 0.966). J0 and J45 crosscylinder power values were not correlated between retinoscopy and SVS (ICC: 0.472) or retinoscopy and tabletop autorefractometer (ICC: 0.442). Retinoscopy was correlated with both SVS and tabletop autorefractometer for all parameters within ±1.96 standard deviations in Bland-Altman analysis. Conclusion: Cycloplegic retinoscopy is the gold standard for refractive error measurement in the pediatric population. However, it requires time and experienced professionals. This study revealed moderate to good agreement between SVS and retinoscopy, with better agreement in spherical errors than cylindrical errors. Although the SVS is intended for screening programs, it may also be useful in the pediatric eye office to estimate spherical refractive error in uncooperative patients.